NR 440.65(5)(b)1.1. The continuous monitoring device shall be calibrated annually and have an accuracy of ±0.75% of the temperature being measured, expressed in degrees Celsius, or ±2.5°C, whichever is greater.
NR 440.65(5)(b)2.2. During the performance test the owner or operator shall determine and record the average temperature of the control device exhaust gases. After the performance test the owner or operator shall determine and record, in addition to the record made by the continuous monitoring device, the average temperature for each 3-hour clock period of printing operation when the average temperature of the exhaust gases is more than 28°C (50°F) below the average temperature demonstrated during the most recent performance test.
NR 440.65(5)(c)(c) The owner or operator of an affected facility controlled by a catalytic incineration emission control device shall install, calibrate, operate and maintain monitoring devices that continuously measure and record the gas temperatures both upstream and downstream of the catalyst bed and shall comply with the following requirements:
NR 440.65(5)(c)1.1. Each continuous monitoring device shall be calibrated annually and have an accuracy of ±0.75% of the temperature being measured, expressed in degrees Celsius, or ±2.5°C, whichever is greater.
NR 440.65(5)(c)2.2. During the performance test the owner or operator shall determine and record the average gas temperature both upstream and downstream of the catalyst bed. After the performance test the owner or operator shall determine and record, in addition to the record made by the continuous monitoring device, the average temperatures for each 3-hour clock period of printing operation when the average temperature of the gas stream before the catalyst bed is more than 28°C (50°F) below the average temperature demonstrated during the most recent performance test or the average temperature difference across the catalyst bed is less than 80 percent of the average temperature difference of the device during the most recent performance test.
NR 440.65(5)(d)(d) The owner or operator of an affected facility shall record time periods of operation when an emission control device is not in use.
NR 440.65(6)(6)Reporting requirements.
NR 440.65(6)(a)(a) For all affected facilities subject to compliance with sub. (3) the performance test data and results from the performance test shall be submitted to the department as specified in s. NR 440.08 (1).
NR 440.65(6)(b)(b) The owner or operator of each affected facility shall submit semiannual reports to the department of occurrences of the following:
NR 440.65(6)(b)1.1. Exceedances of the weighted average VOC content specified in sub. (3) (a) 1.;
NR 440.65(6)(b)2.2. Exceedances of the average value of the exhaust vent VOC concentration as defined under sub. (5) (a) 2.;
NR 440.65(6)(b)3.3. Drops in the incinerator temperature as defined under sub. (5) (b) 2.; and
NR 440.65(6)(b)4.4. Drops in the average temperature of the gas stream immediately before the catalyst bed or drops in the average temperature across the catalyst bed as defined under sub. (5) (c) 2.
NR 440.65(6)(c)(c) The reports required under par. (b) shall be postmarked within 30 days following the end of the second and fourth calendar quarters.
NR 440.65 HistoryHistory: Cr. Register, September, 1986, No. 369, eff. 10-1-86; (2) (a) (intro.) and (b) (intro.), r. (6) (d), Register, September, 1990, No. 417, eff. 10-1-90; CR 06-109: am. (2) (a) 6. and (b) 15. to 17., (4) (a) (intro.) and 1., (b) 4. and 5. and (c) 2. to 4. and (5) (b) 1. and 2. and (c) 1. Register May 2008 No. 629, eff. 6-1-08.
NR 440.66NR 440.66Equipment leaks of VOC in petroleum refineries.
NR 440.66(1)(1)Applicability and designation of affected facility.
NR 440.66(1)(a)(a)
NR 440.66(1)(a)1.1. The provisions of this section apply to affected facilities in petroleum refineries.
NR 440.66(1)(a)2.2. A compressor is an affected facility.
NR 440.66(1)(a)3.3. The group of all the equipment (defined in sub. (2)) within a process unit is an affected facility.
NR 440.66(1)(b)(b) Any affected facility under par. (a) that commences construction or modification after January 4, 1983, is subject to the requirements of this section.
NR 440.66(1)(c)(c) Addition or replacement of equipment (defined in sub. (2)) for the purpose of process improvement which is accomplished without a capital expenditure may not by itself be considered a modification under this section.
NR 440.66(1)(d)(d) Facilities subject to s. NR 440.62 or 440.68 are excluded from this section.
NR 440.66(2)(2)Definitions. As used in this section, terms not defined in this subsection have the meanings given in s. NR 440.02 or 440.62.
NR 440.66(2)(a)(a) “Alaskan north slope” means the approximately 69,000 square mile area extending from the Brooks Range to the Arctic Ocean.
NR 440.66(2)(b)(b) “Equipment” means each valve, pump, pressure relief device, sampling connection system, open-ended valve or line and flange or other connector in VOC service. Compressors are considered equipment only for the purposes of recordkeeping and reporting.
NR 440.66(2)(c)(c) “In hydrogen service” means that a compressor contains a process fluid that meets the conditions in sub. (4) (b).
NR 440.66(2)(d)(d) “In light liquid service” means that the piece of equipment contains a liquid that meets the conditions specified in sub. (4) (c).