NR 811.22(1)(1) Velocity of flow .25 to .50 feet per second through the inlet structure so that frazil ice will be held to a minimum. NR 811.22(1m)(1m) Sufficient opening area to minimize headloss shall be provided when buried surface water collectors are used. Particular attention should be given to the selection of backfill material in relation to the collector pipe slot size and gradation of the native material over the collector system. NR 811.22 NoteNote: The department recommends water systems using a surface water supply source include redundant intakes or an alternate means of supplying the maximum day water demand.
NR 811.22(2)(2) Withdrawal of water from the depth of the best water quality or the capability to draw from more than one level or more than one location if water quality varies with depth or location or both. NR 811.22(4)(4) Adequate protection against rupture by dragging anchors, ice, and other activity. NR 811.22(5)(5) Locations referenced by permanent monuments or latitude and longitude as measured by a Global Positioning System (GPS). NR 811.22(6)(6) A diversion device capable of keeping large quantities of fish or debris from entering an intake structure where shore wells are not provided. NR 811.22 HistoryHistory: CR 09-073: cr. Register November 2010 No. 659, eff. 12-1-10; CR 22-074: cr. (1m), am. (3), cr. (3m) Register January 2024 No. 817, eff. 2-1-24. NR 811.23(1)(1) Shore well structures shall comply with all of the following: NR 811.23(1)(a)(a) Have motors and electrical controls located above grade and above flood level. NR 811.23(1)(d)(d) Be equipped with a minimum of 2 removable or traveling screens or an equivalent means of screening before the pump suction well. Systems with only one screen shall be provided with a bypass. NR 811.23(1)(e)(e) Provide chlorination or other chemical addition facilities for raw water transmission mains. NR 811.23(1)(f)(f) Have the intake piping valved with provisions for backflushing, testing for leaks, and control of frazil ice. NR 811.23(1)(i)(i) Be designed so sanitary sewer and finished water piping located within the shore well is installed in a manner to protect the shore well water quality and preserve the quality of the finished water. It is recommended that piping not be installed above the shore well to allow for access to the piping for routine maintenance. NR 811.23(1)(j)(j) Water discharged from traveling screens and hub drains within the shore well station may discharge into the shore well. NR 811.23(2)(2) The requirements in sub. (1) may be waived by the department on a case-by-case basis if it is demonstrated that they are not necessary to fulfill the other requirements of this chapter. NR 811.23 HistoryHistory: CR 09-073: cr. Register November 2010 No. 659, eff. 12-1-10; CR 22-074: am. (1) (f), cr. (1) (i), (j) Register January 2024 No. 817, eff. 2-1-24. NR 811.231NR 811.231 Off-Stream raw water storage. NR 811.231(1)(1) Definition. In this section, “off-stream raw water storage reservoir” is defined as a facility into which water is pumped during periods of good quality and high stream flow for future release to the treatment facilities. NR 811.231(2)(2) Construction. Off-stream raw water storage reservoirs shall be constructed to assure all of the following: NR 811.231(2)(a)(a) Water quality is protected by controlling runoff into the reservoir.