NR 670.019(3)(a)5.5. A quantification of those hazardous constituents in the waste which may be designated as POHC’s based on data submitted from other trial or operational burns which demonstrate compliance with the performance standards in s. NR 664.0343.
NR 670.019(3)(b)(b) A detailed engineering description of the incinerator, including all of the following:
NR 670.019(3)(b)1.1. Manufacturer’s name and model number of incinerator.
NR 670.019(3)(b)2.2. Type of incinerator.
NR 670.019(3)(b)3.3. Linear dimension of incinerator unit including cross sectional area of combustion chamber.
NR 670.019(3)(b)4.4. Description of auxiliary fuel system (type/feed).
NR 670.019(3)(b)5.5. Capacity of prime mover.
NR 670.019(3)(b)6.6. Description of automatic waste feed cutoff systems.
NR 670.019(3)(b)7.7. Stack gas monitoring and pollution control monitoring system.
NR 670.019(3)(b)8.8. Nozzle and burner design.
NR 670.019(3)(b)9.9. Construction materials.
NR 670.019(3)(b)10.10. Location and description of temperature, pressure and flow indicating devices and control devices.
NR 670.019(3)(c)(c) A description and analysis of the waste to be burned compared with the waste for which data from operational or trial burns are provided to support the contention that a trial burn is not needed. The data shall include those items listed in par. (a). This analysis shall specify the POHCs which the applicant has identified in the waste for which a license is sought, and any differences from the POHCs in the waste for which burn data are provided.
NR 670.019(3)(d)(d) The design and operating conditions of the incinerator unit to be used, compared with that for which comparative burn data are available.
NR 670.019(3)(e)(e) A description of the results submitted from any previously conducted trial burns including all of the following:
NR 670.019(3)(e)1.1. Sampling and analysis techniques used to calculate performance standards in s. NR 664.0343.
NR 670.019(3)(e)2.2. Methods and results of monitoring temperatures, waste feed rates, carbon monoxide and an appropriate indicator of combustion gas velocity (including a statement concerning the precision and accuracy of this measurement).
NR 670.019(3)(f)(f) The expected incinerator operation information to demonstrate compliance with ss. NR 664.0343 and 664.0345 including all of the following:
NR 670.019(3)(f)1.1. Expected carbon monoxide (CO) level in the stack exhaust gas.
NR 670.019(3)(f)2.2. Waste feed rate.
NR 670.019(3)(f)3.3. Combustion zone temperature.
NR 670.019(3)(f)4.4. Indication of combustion gas velocity.
NR 670.019(3)(f)5.5. Expected stack gas volume, flow rate and temperature.
NR 670.019(3)(f)6.6. Computed residence time for waste in the combustion zone.
NR 670.019(3)(f)7.7. Expected hydrochloric acid removal efficiency.
NR 670.019(3)(f)8.8. Expected fugitive emissions and their control procedures.
NR 670.019(3)(f)9.9. Proposed waste feed cut-off limits based on the identified significant operating parameters.
NR 670.019(3)(g)(g) Supplemental information as the department finds necessary to achieve the purposes of this subsection.
NR 670.019(3)(h)(h) Waste analysis data, including that submitted in sub. (3) (a), sufficient to allow the department to specify in the license those principal organic hazardous constituents (license POHCs) for which destruction and removal efficiencies will be required.