ATCP 76.13(1)(c)2.e.e. Describes what safety measures that must be employed during monthly testing. P ATCP 76.13(1)(c)3.3. Once monthly, challenge testing of the chemical feeder system shall be conducted to assess the interlock pursuant to subd. 1. P ATCP 76.13(1)(c)4.4. A log of the monthly test shall be kept and meet all of the following: ATCP 76.13(1)(c)4.a.a. Documented with the date, results, and the name of the person performing the test. P ATCP 76.13(1)(c)5.5. The system flow sensing interlock requirement does not apply to pools constructed before February 2009, unless the pool has been involved in a chemical release incident in which the installation of a flow sensing interlock would have prevented the chemical release. ATCP 76.13(2)(a)(a) Maintenance hazards. All maintenance that presents a danger to the patrons, including changing chlorine gas tanks and testing interlocks, shall be performed when the pool is not in use or is closed to public use. P ATCP 76.13(2)(b)(b) Maintenance signage. When access to a pool or pool area cannot be restricted, signage shall be in place indicating that the pool is closed, and the area shall be monitored to ensure the pool is not in use. This would include a pool area that contains more than one pool, but not all of the pools are closed. This applies to hotels with pools built before February 1, 2017, with access to the pool area through the guest room. P ATCP 76.13(3)(3) Repairs. Only personnel trained and licensed in handling gas chlorine by a certifying agency such as the federal occupational health and safety administration may repair gas chlorinators. Pf ATCP 76.13(4)(4) Evacuation during chemical feed incident. If the interlock is activated stopping flow from the chemical feeders, or the water recirculation pump is stopped manually or unexpectedly for any reason and duration, including power outages, all patrons shall be evacuated from the pool until manual evaluation of the cause for interlock activation or recirculation pump interruption is completed by the responsible supervisor or pool operator. P ATCP 76.13 HistoryHistory: CR 22-021: cr. Register June 2023 No. 810, eff. 9-24-23; correction in (1) (c) (intro.), 2. (intro.) made under s. 35.17, Stats., Register June 2023. ATCP 76.14ATCP 76.14 Disinfectant or sanitizer feeding and residuals. ATCP 76.14(1)(1) General. Each pool in use shall be automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13. P ATCP 76.14(2)(a)(a) Disinfectant or sanitizer-producing chlorine and bromine and other chemicals. Disinfectant or sanitizer-producing chlorine or bromine and any supplemental or alternative chemical used shall meet all the following requirements: ATCP 76.14(2)(a)1.1. Registered with the United States environmental protection agency as a disinfectant or sanitizer, except algaecides shall be registered as algaecide. Pf ATCP 76.14(2)(a)3.3. Has an effective residual that can be measured easily and accurately by an approved field test procedure. Pf ATCP 76.14(2)(a)4.4. Is compatible for use with other chemicals normally used in the water treatment or is clearly identified as having a use limitation. Pf ATCP 76.14(2)(a)5.5. Does not impart toxic properties to the patrons in the water when used according to the manufacturer’s directions. P ATCP 76.14(2)(a)6.6. Does not create an undue safety hazard when handled, stored, or used according to the manufacturer’s directions. P ATCP 76.14(2)(b)(b) Bromine. Bromine may not be used in a waterslide, pool slide, plunge pool, or wave pool without the department’s approval. ATCP 76.14(2)(c)(c) Cyanuric acid. Cyanuric acid-containing disinfectant or sanitizer may not be used at an indoor pool, therapy pool, or whirlpool, beginning September 24, 2025. ATCP 76.14(3)(3) Gas chlorination cylinders. Gas chlorination cylinders shall be all the following: ATCP 76.14(3)(a)(a) Upright. A cylinder shall be in an upright position and other container types shall be placed per manufacturer’s instructions. Pf ATCP 76.14(3)(b)(b) Chained. A cylinder shall be chained or strapped to a rigid support. Pf ATCP 76.14(3)(c)(c) Moving cylinders. Cylinders may not be moved unless the protection cap is secured over the valve. Pf ATCP 76.14(3)(d)(d) Tagged. An empty cylinder shall be tagged to indicate they are empty. Pf