NR 670.015(1)(e)(e) How accumulated liquids can be analyzed and removed to prevent overflow.
NR 670.015(2)(2)For storage areas that store containers holding wastes that do not contain free liquids, a demonstration of compliance with s. NR 664.0175 (3), including all of the following:
NR 670.015(2)(a)(a) Test procedures and results or other documentation or information to show that the wastes do not contain free liquids.
NR 670.015(2)(b)(b) A description of how the storage area is designed or operated to drain and remove liquids or how containers are kept from contact with standing liquids.
NR 670.015(3)(3)Sketches, drawings or data demonstrating compliance with s. NR 664.0176 (location of buffer zone and containers holding ignitable or reactive wastes) and s. NR 664.0177 (3) (location of incompatible wastes), where applicable.
NR 670.015(4)(4)Where incompatible wastes are stored or otherwise managed in containers, a description of the procedures used to ensure compliance with ss. NR 664.0177 (1) and (2), and 664.0017 (2) and (3).
NR 670.015(5)(5)Information on air emission control equipment as required in s. NR 670.027.
NR 670.015 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 670.016NR 670.016Specific feasibility and plan of operation report information requirements for tank systems. Except as otherwise provided in s. NR 664.0190, owners and operators of facilities that use tanks to store or treat hazardous waste shall provide all of the following additional information:
NR 670.016(1)(1)A written assessment that is reviewed and certified by a qualified professional engineer as to the structural integrity and suitability for handling hazardous waste of each tank system, as required under ss. NR 664.0191 and 664.0192.
NR 670.016(2)(2)Dimensions and capacity of each tank.
NR 670.016(3)(3)Description of feed systems, safety cutoff, bypass systems and pressure controls (e.g., vents).
NR 670.016(4)(4)A diagram of piping, instrumentation and process flow for each tank system.
NR 670.016(5)(5)A description of materials and equipment used to provide external corrosion protection, as required under s. NR 664.0192 (1) (c) 2.
NR 670.016(6)(6)For new tank systems, a detailed description of how the tank systems will be installed in compliance with s. NR 664.0192 (2), (3), (4) and (5).
NR 670.016(7)(7)Detailed plans and description of how the secondary containment system for each tank system is or will be designed, constructed and operated to meet s. NR 664.0193 (1), (2), (3), (4), (5) and (6).
NR 670.016(8)(8)Any of the following for tank systems for which an alternative to the requirements of s. NR 664.0193 is sought (as provided by s. NR 664.0193 (7)):
NR 670.016(8)(a)(a) Detailed plans and engineering and hydrogeologic reports, as appropriate, describing alternate design and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous waste or hazardous constituents into the groundwater or surface water during the life of the facility.
NR 670.016(8)(b)(b) A detailed assessment of the substantial present or potential hazards posed to human health or the environment should a release enter the environment.
NR 670.016(9)(9)Description of controls and practices to prevent spills and overflows, as required under s. NR 664.0194 (2).
NR 670.016(10)(10)For tank systems in which ignitable, reactive or incompatible wastes are to be stored or treated, a description of how operating procedures and tank system and facility design will achieve compliance with ss. NR 664.0198 and 664.0199.
NR 670.016(11)(11)Information on air emission control equipment as required in s. NR 670.027.
NR 670.016 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 16-007: am. (1) Register July 2017 No. 739, eff. 8-1-17.
NR 670.017NR 670.017Specific feasibility and plan of operation report information requirements for surface impoundments. Except as otherwise provided in s. NR 664.0001, owners and operators of facilities that store, treat or dispose of hazardous waste in surface impoundments shall provide all of the following additional information:
NR 670.017(1)(1)A list of the hazardous wastes placed or to be placed in each surface impoundment.
NR 670.017(2)(2)Detailed plans and an engineering report describing how the surface impoundment is designed and is or will be constructed, operated and maintained to meet ss. NR 664.0019, 664.0221, 664.0222 and 664.0223, addressing all of the following items:
NR 670.017(2)(a)(a) The liner system (except for an existing portion of a surface impoundment). If an exemption from the requirement for a liner is sought as provided by s. NR 664.0221 (2), submit detailed plans and engineering and hydrogeologic reports, as appropriate, describing alternate design and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous constituents into the groundwater or surface water at any future time.
NR 670.017(2)(b)(b) The double liner and leak (leachate) detection, collection and removal system, if the surface impoundment shall meet s. NR 664.0221 (3). If an exemption from the requirements for double liners and a leak detection, collection, and removal system or alternative design is sought as provided by s. NR 664.0221 (4), (5) or (6), submit appropriate information.
NR 670.017(2)(c)(c) If the leak detection system is located in a saturated zone, submit detailed plans and an engineering report explaining the leak detection system design and operation, and the location of the saturated zone in relation to the leak detection system.