(Equation 17)
NR 466.07(7)(7)Operating more than one capture system or control device, or one or more never-controlled or intermittently-controllable work stations. This subsection applies to owners or operators of product and packaging rotogravure or wide-web flexographic printing presses operating more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controllable work stations.
NR 466.07(7)(a)(a) The owner or operator of each solvent recovery system used to control one or more product and packaging rotogravure or wide-web flexographic presses for which the owner or operator chooses to perform a liquid-liquid material balance under sub. (4) (a) 1. shall determine the organic HAP emissions for those presses controlled by that solvent recovery system according to one of the following:
NR 466.07(7)(a)1.1. In accordance with sub. (4) (a) 1. a. to c. and e. to h., if the presses controlled by that solvent recovery system have only always-controlled work stations.
NR 466.07(7)(a)2.2. In accordance with subs. (4) (a) 1. b., c., e. and f. and (8), if the presses controlled by that solvent recovery system have one or more never-controlled or intermittently-controllable work stations.
NR 466.07(7)(b)(b) The owner or operator of each solvent recovery system used to control one or more product and packaging rotogravure or wide-web flexographic presses, for which the owner or operator chooses to conduct continuous emission monitoring of the control device, conduct an initial test of capture efficiency, and continuously monitor a site specific operating parameter to assure capture efficiency under sub. (4) (a) 2., shall do both of the following:
NR 466.07(7)(b)1.1. For each capture system delivering emissions to that solvent recovery system, monitor an operating parameter established in accordance with s. NR 466.10 (6) to assure capture system efficiency.
NR 466.07(7)(b)2.2. Determine the organic HAP emissions for those presses served by each capture system delivering emissions to that solvent recovery system according to one of the following:
NR 466.07(7)(b)2.a.a. In accordance with sub. (4) (a) 2. a. to c. and e. to h., if the presses served by that capture system have only always-controlled work stations.
NR 466.07(7)(b)2.b.b. In accordance with subs. (4) (a) 2. b., c. and e. to g. and (8), if the presses served by that capture system have one or more never-controlled or intermittently-controllable work stations.
NR 466.07(7)(c)(c) The owner or operator of each oxidizer used to control emissions from one or more product and packaging rotogravure or wide-web flexographic presses, for which the owner or operator chooses to conduct performance tests of capture efficiency and control device efficiency and continuously monitor capture system and control device operating parameters under sub. (5) (a) 1., shall do all of the following:
NR 466.07(7)(c)1.1. Monitor an operating parameter established in accordance with s. NR 466.10 (5) to assure control device efficiency.
NR 466.07(7)(c)2.2. For each capture system delivering emissions to that oxidizer, monitor an operating parameter established in accordance with s. NR 466.10 (6) to assure capture efficiency.
NR 466.07(7)(c)3.3. Determine the organic HAP emissions for those presses served by each capture system delivering emissions to that oxidizer according to one of the following:
NR 466.07(7)(c)3.a.a. In accordance with sub. (5) (a) 1. a. to e. and g., if the presses served by that capture system have only always-controlled work stations.
NR 466.07(7)(c)3.b.b. In accordance with subs. (5) (a) 1. a. to c. and e. and (8), if the presses served by that capture system have one or more never-controlled or intermittently-controllable work stations.
NR 466.07(7)(d)(d) The owner or operator of each oxidizer used to control emissions from one or more product and packaging rotogravure or wide-web flexographic presses, for which the owner or operator chooses to conduct continuous emission monitoring of the control device, conduct an initial performance test of capture efficiency and continuously monitor a site specific operating parameter to assure capture efficiency under sub. (5) (a) 2., shall do both of the following:
NR 466.07(7)(d)1.1. For each capture system delivering emissions to that oxidizer, monitor an operating parameter established in accordance with s. NR 466.10 (6) to assure capture efficiency.
NR 466.07(7)(d)2.2. Determine the organic HAP emissions for those presses served by each capture system delivering emissions to that oxidizer according to one of the following:
NR 466.07(7)(d)2.a.a. In accordance with sub. (4) (a) 2. a. to c. and e. to h., if the presses served by that capture system have only always-controlled work stations.
NR 466.07(7)(d)2.b.b. In accordance with subs. (4) (a) 2. b., c., e. to g. and (8), if the presses served by that capture system have one or more never-controlled or intermittently-controllable work stations.
NR 466.07(7)(e)(e) The owner or operator of one or more uncontrolled product and packaging rotogravure or wide-web flexographic printing presses shall determine the organic HAP applied on those presses using Equation 8 in sub. (3) (f). For the purpose of a determination under this paragraph, the organic HAP emitted from an uncontrolled press shall be considered equal to the organic HAP applied on that press.
NR 466.07(7)(f)(f) If demonstrating compliance with sub. (2) (c) or (d), the owner or operator shall determine the solids content of each ink, coating, varnish, adhesive, primer, solvent and other material applied during the month following the procedure in s. NR 466.09 (3) (b).
NR 466.07(7)(g)(g) The owner or operator shall determine the organic HAP emissions for the affected source for the month by summing all organic HAP emissions calculated according to pars. (a), (b) 2., (c) 3., (d) 2. and (e).
NR 466.07(7)(h)(h) Under this subsection, the affected source is in compliance for the month with an emission limitation, if all operating parameters required to be monitored under pars. (b) to (d), were maintained at the appropriate values, and one of the following is satisfied:
NR 466.07(7)(h)1.1. The total mass of organic HAP emitted by the affected source was not more than 4% of the total mass of inks, coatings, varnishes, adhesives, primers, solvents, diluents, reducers, thinners and other materials applied by the affected source.
NR 466.07(7)(h)2.2. The total mass of organic HAP emitted by the affected source was not more than 20% of the total mass of solids applied by the affected source.
NR 466.07(7)(h)3.3. The total mass of organic HAP emitted by the affected source was not more than the equivalent allowable organic HAP emissions for the affected source, Ha, calculated in accordance with sub. (6).