NR 440.26(2)(g)(g) “Fuel gas” means any gas which is generated at a petroleum refinery and which is combusted. Fuel gas also includes natural gas when the natural gas is combined and combusted in any proportion with a gas generated at a refinery. Fuel gas does not include gases generated by catalytic cracking unit catalyst regenerators and fluid coking burners. NR 440.26(2)(h)(h) “Fuel gas combustion device” means any equipment, such as process heaters, boilers and flares used to combust fuel gas, except facilities in which gases are combusted to produce sulfur or sulfuric acid. NR 440.26(2)(i)(i) “Oxidation control system” means an emission control system which reduces emissions from sulfur recovery plants by converting these emissions to sulfur dioxide. NR 440.26(2)(j)(j) “Petroleum” means the crude oil removed from the earth and the oils derived from tar sands, shale and coal. NR 440.26(2)(k)(k) “Petroleum refinery” means any facility engaged in producing gasoline, kerosene, distillate fuel oils, residual fuel oils, lubricants or other products through distillation of petroleum or through redistillation, cracking or reforming of unfinished petroleum derivatives. NR 440.26(2)(L)(L) “Process gas” means any gas generated by a petroleum refinery process unit, except fuel gas and process upset gas as defined in this subsection. NR 440.26(2)(m)(m) “Process upset gas” means any gas generated by a petroleum refinery process unit as a result of startup, shutdown, upset or malfunction. NR 440.26(2)(n)(n) “Reduced sulfur compounds” means hydrogen sulfide (H2S), carbonyl sulfide (COS) and carbon disulfide (CS2). NR 440.26(2)(o)(o) “Reduction control system” means an emission control system which reduces emissions from sulfur recovery plants by converting these emissions to hydrogen sulfide. NR 440.26(2)(p)(p) “Refinery process unit” means any segment of the petroleum refinery in which a specific processing operation is conducted. NR 440.26(2)(q)(q) “Valid day” means a 24-period in which at least 18 valid hours of data are obtained. A “valid hour” is one in which at least 2 valid data points are obtained. NR 440.26(3)(3) Standard for particulate matter. Each owner or operator of any fluid catalytic cracking unit catalyst regenerator that is subject to the requirements of this section shall comply with the emission limitations set forth in this subsection on and after the date on which the initial performance test, required by s. NR 440.08, is completed, but not later than 60 days after achieving the maximum production rate at which the fluid catalytic cracking unit catalyst regenerator will be operated, or 180 days after initial startup, whichever comes first. NR 440.26(3)(a)(a) No owner or operator subject to the provisions of this section may discharge or cause the discharge into the atmosphere from any fluid catalytic cracking unit catalyst regenerator: NR 440.26(3)(a)1.1. Particulate matter in excess of 1.0 kg/Mg (2.0 lb/ton) of coke burn-off in the catalyst regenerator. NR 440.26(3)(a)2.2. Gases exhibiting greater than 30% opacity, except for one 6-minute average opacity reading in any one hour period. NR 440.26(3)(b)(b) Where the gases discharged by the fluid catalytic cracking unit catalyst regenerator pass through an incinerator or waste heat boiler in which auxiliary or supplemental liquid or solid fossil fuel is burned, particulate matter in excess of that permitted by par. (a) 1. may be emitted to the atmosphere, except that the incremental rate of particulate matter emissions may not exceed 43.0 g/MJ (0.10 lb/million Btu) of heat input attributable to such liquid or solid fossil fuel. NR 440.26(4)(4) Standard for carbon monoxide. Each owner or operator of any fluid catalytic cracking unit catalyst regenerator that is subject to the requirements of this section shall comply with the emission limitations set forth in this subsection on and after the date on which the initial performance test, required by s. NR 440.08, is completed, but not later than 60 days after achieving the maximum production rate at which the fluid catalytic cracking unit catalyst regenerator will be operated, or 180 days after initial startup, whichever comes first. NR 440.26(4)(a)(a) No owner or operator subject to the provisions of this section may discharge or cause the discharge into the atmosphere from any fluid catalytic cracking unit catalyst regenerator any gases that contain carbon monoxide (CO) in excess of 500 ppm by volume (dry basis). NR 440.26(5)(5) Standard for sulfur dioxide. Each owner or operator that is subject to the requirements of this section shall comply with the emission limitations set forth in this subsection on and after the date on which the initial performance test, required by s. NR 440.08, is completed, but not later than 60 days after achieving the maximum production rate at which the affected facility will be operated, or 180 days after initial startup, whichever comes first. NR 440.26(5)(a)(a) No owner or operator subject to the provisions of this section may: NR 440.26(5)(a)1.1. Burn in any fuel gas combustion device any fuel gas that contains hydrogen sulfide (H2S) in excess of 230 mg/dscm (0.10 gr/dscf). The combustion in a flare of process upset gases or fuel gas that is released to the flare as a result of relief valve leakage or other emergency malfunctions is exempt from this paragraph. NR 440.26(5)(a)2.2. Discharge or cause the discharge of any gases into the atmosphere from any Claus sulfur recovery plant containing in excess of: NR 440.26(5)(a)2.a.a. For an oxidation control system or a reduction control system followed by incineration, 250 ppm by volume (dry basis) of sulfur dioxide (SO2) at zero percent excess air. NR 440.26(5)(a)2.b.b. For a reduction control system not followed by incineration, 300 ppm by volume of reduced sulfur compounds and 10 ppm by volume of hydrogen sulfide (H2S), each calculated as ppm SO2 by volume (dry basis) at zero percent excess air. NR 440.26(5)(b)(b) Each owner or operator that is subject to the provisions of this section shall comply with one of the following conditions for each affected fluid catalytic cracking unit catalyst regenerator: NR 440.26(5)(b)1.1. With an add-on control device, reduce sulfur dioxide emissions to the atmosphere by 90% or maintain sulfur dioxide emissions to the atmosphere less than or equal to 50 ppm by volume (ppmv), whichever is less stringent. NR 440.26(5)(b)2.2. Without the use of an add-on control device, maintain sulfur oxides emissions calculated as sulfur dioxide to the atmosphere less than or equal to 9.8 kg/Mg (20 lb/ton) coke burn-off. NR 440.26(5)(b)3.3. Process in the fluid catalytic cracking unit fresh feed that has a total sulfur content no greater than 0.30% by weight. NR 440.26(5)(c)(c) Compliance with par. (b) 1., 2. or 3. is determined daily on a 7-day rolling average basis using the appropriate procedures outlined in sub. (7).