NR 432.05(1)(a)1.1. For a CAIR NOx unit that is a cogeneration unit and that has operated for 5 or more consecutive calendar years, by using one of the following equations: NR 432.05(1)(a)1.a.a. Use equation 1a if the unit is the only unit serving a generator or, if more than one unit serves the same generator and unit-level data for equation 9a is available for all units: where:
B is the unit baseline energy output made available by the cogeneration unit in MWh
GEavg is the average of the 3 highest annual amounts of the unit’s ozone season gross electric output in MWh over the 5-year period identified in par. (b)
TEavg is the average of the 3 highest annual amounts of the unit’s ozone season useful thermal energy in mmBtu over the 5-year period identified in par. (b)
3.4 is a conversion factor in mmBtu/MWh
NR 432.05(1)(a)1.b.b. Use equation 9b if more than one unit serves the same generator and unit-level data for equation 9a is not available for all units: where:
Bi is the baseline energy output made available by cogeneration unit i in MWh
GEGen is the average of the 3 highest annual amounts of the ozone season gross electric output in MWh for the generator served over the 5-year period identified in par. (b)
TET is the average of the 3 highest annual amounts of ozone season useful thermal energy in mmBtu for the generator served over the 5-year period defined in par. (b)
3.4 is a conversion factor in mmBtu/MWh
NCi is the nameplate capacity of unit i
n is the number of units serving the same generator
NR 432.05(1)(a)2.2. For a CAIR NOx unit that is not a cogeneration unit and that has operated for 5 or more consecutive calendar years and for a CAIR renewable unit that has operated for 5 or more consecutive calendar years, by using one of the following equations as appropriate: NR 432.05(1)(a)2.a.a. Use equation 10a if the unit is the only unit serving a generator or, if more than one unit serves the same generator and unit-level data for equation 10a is available for all units: where:
B is the unit baseline energy output made available by the CAIR NOx unit or the CAIR renewable unit in MWh
GEavg is the average of the 3 highest annual amounts of the unit’s ozone season gross electric output in MWh over the 5-year period identified in par. (b)
NR 432.05(1)(a)2.b.b. Use equation 10b if more than one unit serves the same generator and unit-level data for equation 10a is not available for all units: where:
Bi is the baseline energy output made available by CAIR NOx unit i or CAIR renewable unit i in MWh
GEGen is the average of the 3 highest annual amounts of the ozone season gross electric output in MWh for the generator served over the 5-year period identified in par. (b)
NCi is the nameplate capacity of unit i