NR 465.06(1)(c)1.1. Use contact adhesives with a VHAP content no greater than 1.0 kg VHAP/kg solids (1.0 lb VHAP/lb solids), as applied.
NR 465.06(1)(c)2.2. Use a control system with an overall control efficiency (R) such that the value of Gac in Equation 3 is no greater than 1.0.
(Equation 3)
NR 465.06(2)(2)New sources.
NR 465.06(2)(a)(a) Finishing materials. The owner or operator of a new affected source shall comply with s. NR 465.04 (2) (a) by using any of the following methods:
NR 465.06(2)(a)1.1. Calculate the average VHAP content across all finishing materials used at the facility using Equation 1 in sub. (1) (a) 1., and maintain a value of E no greater than 0.8.
NR 465.06(2)(a)2.2. Use compliant finishing materials according to the following criteria:
NR 465.06(2)(a)2.a.a. Demonstrate that each sealer and topcoat has a VHAP content of no more than 0.8 kg VHAP/kg solids (0.8 lb VHAP/lb solids), as applied, each stain has a VHAP content of no more than 1.0 kg VHAP/kg solids (1.0 lb VHAP/lb solids), as applied, and each thinner contains no more than 10.0% VHAP by weight by maintaining certified product data sheets for each coating and thinner.
NR 465.06(2)(a)2.b.b. Demonstrate that each washcoat, basecoat and enamel that is not formulated at the affected source by thinning another finishing material has a VHAP content of no more than 0.8 kg VHAP/kg solids (0.8 lb VHAP/lb solids), as applied, and each thinner contains no more than 10.0% VHAP by weight by maintaining certified product data sheets for each coating and thinner.
NR 465.06(2)(a)2.c.c. Demonstrate that each washcoat, basecoat and enamel that is formulated at the affected source is formulated using a finishing material containing no more than 0.8 kg VHAP/kg solids (0.8 lb VHAP/lb solids) and a thinner containing no more than 3.0% VHAP by weight.
NR 465.06(2)(a)3.3. Use a control system with an overall control efficiency (R) such that the value of Eac in Equation 4 is no greater than 0.8. The value of Ebc in Equation 4 shall be calculated using Equation 1 in sub. (1) (a) 1.
(Equation 4)
NR 465.06(2)(a)4.4. Use any combination of the methods in subds. 1. to 3.
NR 465.06(2)(b)(b) Contact adhesives. The owner or operator of a new affected source shall comply with s. NR 465.04 (2) (b) by using either of the following methods:
NR 465.06(2)(b)1.1. Use contact adhesives with a VHAP content no greater than 0.2 kg VHAP/kg solids (0.2 lb VHAP/lb solids), as applied.
NR 465.06(2)(b)2.2. Use a control system with an overall control efficiency (R) such that the value of Gac in Equation 3 in sub. (1) (c) 2. is no greater than 0.2.
NR 465.06 HistoryHistory: CR 00-160: cr. Register August 2001 No. 548, eff. 9-1-01.
NR 465.07NR 465.07Initial compliance demonstration.
NR 465.07(1)(1)Finishing materials. The owner or operator of an affected source subject to the provisions of s. NR 465.04 (1) (a) or (2) (a) shall demonstrate initial compliance according to the following procedures as appropriate:
NR 465.07(1)(a)(a) If complying by using the methods in s. NR 465.06 (1) (a) 1. or (2) (a) 1., submit the results of the averaging calculation using Equation 1 in s. NR 465.06 (1) (a) 1. for the first month with the initial compliance status report required by s. NR 465.105 (2). The first month’s calculation shall include data for the entire month in which the compliance date falls.
NR 465.07(1)(b)(b) If complying by using the methods s. NR 465.06 (1) (a) 2. or (2) (a) 2., state in the initial compliance status report under s. NR 465.105 (2) that compliant stains, washcoats, sealers, topcoats, basecoats, enamels and thinners, as applicable, are being used by the affected source.
NR 465.07(1)(c)(c) If complying by using the methods in s. NR 465.06 (1) (a) 2. or (2) (a) 2. and applying coatings using continuous coaters, do one of the following:
NR 465.07(1)(c)1.1. State in the initial compliance status report under s. NR 465.105 (2) that compliant coatings, as determined by the VHAP content of the coating in the reservoir and the VHAP content as calculated from records, and compliant thinners are being used.
NR 465.07(1)(c)2.2. State in the initial compliance status report under s. NR 465.105 (2) that compliant coatings, as determined by the VHAP content of the coating in the reservoir, are being used; the viscosity of the coating in the reservoir is being monitored; and compliant thinners are being used. The owner or operator shall also submit data that demonstrate that viscosity is an appropriate parameter for demonstrating compliance.
NR 465.07(1)(d)(d) If complying by using the methods in s. NR 465.06 (1) (a) 3. or (2) (a) 3., do all of the following:
NR 465.07(1)(d)1.1. Submit a monitoring plan that identifies each operating parameter to be monitored for the capture device and discusses why each parameter is appropriate for demonstrating continuous compliance.
NR 465.07(1)(d)2.2. Conduct an initial performance test as required under s. NR 460.06 using the procedures and test methods listed in ss. NR 460.06 and 465.09 (3) and (4).