NR 661.1064(3)(a)(a) A weatherproof and readily visible identification, marked with the equipment identification number, the date evidence of a potential leak was found in accordance with s. NR 661.1058 (1), and the date the leak was detected, shall be attached to the leaking equipment. NR 661.1064(3)(b)(b) The identification on equipment, except on a valve, may be removed after it has been repaired. NR 661.1064(3)(c)(c) The identification on a valve may be removed after it has been monitored for 2 successive months as specified in s. NR 661.1057 (3) and no leak has been detected during those 2 months. NR 661.1064(4)(a)(a) The instrument and operator identification numbers and the equipment identification number. NR 661.1064(4)(c)(c) The date the leak was detected and the dates of each attempt to repair the leak. NR 661.1064(4)(e)(e) “Above 10,000” if the maximum instrument reading measured by the methods specified in s. NR 661.1063 (2) after each repair attempt is equal to or greater than 10,000 ppm. NR 661.1064(4)(f)(f) “Repair delayed” and the reason for the delay if a leak is not repaired within 15 calendar days after discovery of the leak. NR 661.1064(4)(h)(h) The signature of the remanufacturer or other person that stores or treats the hazardous secondary material, or designee, whose decision it was that repair could not be affected without a hazardous secondary material management unit shutdown. NR 661.1064(4)(i)(i) The expected date of successful repair of the leak if a leak is not repaired within 15 calendar days. NR 661.1064(5)(5) Design documentation and monitoring, operating, and inspection information for each closed-vent system and control device required to comply with the provisions specified in s. NR 661.1060 shall be recorded by the remanufacturer or other person and kept up-to-date at the facility as specified in s. NR 661.1035 (3). Design documentation is specified in s. NR 661.1035 (3) (a) and (b) and monitoring, operating, and inspection information is specified in s. NR 661.1035 (3) (c) to (h). NR 661.1064(6)(6) For a control device other than a thermal vapor incinerator, catalytic vapor incinerator, flare, boiler, process heater, condenser or carbon adsorption system, record, in the facility operating record, monitoring and inspection information indicating proper operation and maintenance of the control device. NR 661.1064(7)(7) A remanufacturer or other person that stores or treats the hazardous secondary material shall record all of the following information, pertaining to all equipment subject to ss. NR 661.1052 to 661.1060, in a log that is kept in the facility operating record: NR 661.1064(7)(a)(a) A list of identification numbers for equipment, except welded fittings, subject to the requirements of this subchapter. NR 661.1064(7)(b)1.1. A list of identification numbers for equipment that the remanufacturer or other person that stores or treats the hazardous secondary material elects to designate for no detectable emissions, as indicated by an instrument reading of less than 500 ppm above background, under the provisions specified in ss. NR 661.1052 (5), 661.1053 (9), and 661.1057 (6). NR 661.1064(7)(d)3.3. The maximum instrument reading measured at the equipment during each compliance test. NR 661.1064(7)(e)(e) A list of identification numbers for equipment in vacuum service. NR 661.1064(7)(f)(f) Identification, either by list or location, such as area or group, of equipment that contains or contacts hazardous secondary material with an organic concentration of at least 10 percent by weight for less than 300 hours per calendar year.