NR 439.06(3)(b)(b) Method 24 or 24A in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), shall be used to determine the organic solvent content, the volume of solids, the weight of solids, the water content and the density of surface coatings, inks, and cleaning materials.
NR 439.06(3)(c)(c) Method 21 in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), shall be used to detect organic compound emission leaks except as provided in par. (i) 2. or 3.
NR 439.06 NoteNote: Section 439.06 (3) (i) was repealed by CR 15-077
NR 439.06(3)(d)(d) Method 27 in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), shall be used to verify the vapor tightness of gasoline delivery tanks.
NR 439.06(3)(e)(e) An equation established under s. NR 425.05 (1) (b) 2. or contained in s. NR 425.05 (2) (b) 2. shall be used to determine compliance with an internal offset.
NR 439.06(3)(f)(f) Methods approved by the department shall be used to determine the transfer efficiency of surface coating equipment.
NR 439.06(3)(g)(g) Method 25A in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), shall be used to determine compliance with the aerosol can filling VOC emission limit in s. NR 424.04. If a flame ionization detector is used to test compliance with s. NR 424.04, test equipment calibration shall be conducted with propane. During the testing procedure, the flame ionization detector shall continuously measure VOC emissions for a minimum of one hour per aerosol can filling line with the control device not in operation and for a minimum of one hour with the control device in full operation. Production data taken concurrently with the testing procedure shall be used to calculate the VOC emission rates for the tested aerosol can filling line when the control device is not in operation and when the control device is in full operation.
NR 439.06(3)(h)(h) Compounds identified in s. NR 400.02 (162) as having negligible photochemical reactivity shall be treated as water to determine compliance with emission limitations which refer to water.
NR 439.06(3)(j)(j) Notwithstanding par. (b), Method 24 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), shall be used to determine the VOC content of lithographic inks, fountain solutions and blanket or roller wash in complying with ss. NR 422.142 and 422.143.
NR 439.06(4)(4)Carbon monoxide emissions. The owner or operator of a source shall use one of the following methods to determine compliance with a carbon monoxide emission limitation:
NR 439.06(4)(a)(a) Method 10, 10A, or 10B in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13).
NR 439.06(4)(b)(b) Install, calibrate, maintain and operate a continuous emission monitor that meets the applicable performance specifications in 40 CFR part 60, Appendix B, incorporated by reference in s. NR 484.04 (21), and follow quality control and quality assurance procedures for the monitor which have been submitted by the owner or operator of the source and approved by the department.
NR 439.06(5)(5)Lead emissions. The owner or operator of a source shall use Method 12 in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), to determine compliance with a lead emission limitation.
NR 439.06(6)(6)Nitrogen compound emissions. The owner or operator of a source shall use one of the following methods to determine compliance with a nitrogen compound emission limitation:
NR 439.06(6)(a)(a) Method 7, 7A, 7B, 7C, 7D, or 7E in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13).
NR 439.06(6)(b)(b) Install, calibrate, maintain and operate a continuous emission monitor that meets the applicable performance specifications in 40 CFR part 60, Appendix B, or, for affected sources, the performance specifications in 40 CFR part 75, Appendices A to I, incorporated by reference in s. NR 484.04 (21) and (27). The owner or operator of the source shall submit and follow the quality control and quality assurance plan for the monitor which has been approved by the department.
NR 439.06(7)(7)Total reduced sulfur emissions. The owner or operator of a source shall use one of the following methods to determine compliance with a total reduced sulfur emission limitation:
NR 439.06(7)(a)(a) Method 15A, 16, 16A, or 16B in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13).
NR 439.06(7)(b)(b) Install, calibrate, maintain and operate a continuous emission monitor that meets the applicable performance specifications in 40 CFR part 60, Appendix B, incorporated by reference in s. NR 484.04 (21), and follow quality control and quality assurance procedures for the monitor which have been submitted by the owner or operator of the source and approved by the department.
NR 439.06(8)(8)Emissions of other air contaminants. The owner or operator of a source shall use methods and plans approved, in writing, by the department to determine compliance with an emission limitation for an air contaminant not listed in subs. (1) to (7).
NR 439.06(9)(9)Methods and procedures for visible emissions.
NR 439.06(9)(a)(a) The owner or operator of a source shall use one of the following methods to determine compliance with a visible emission limitation:
NR 439.06(9)(a)1.1. Method 9 in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13).
NR 439.06(9)(a)2.2. Install, calibrate, maintain and operate a continuous emission monitor that meets the applicable performance specifications in 40 CFR part 60, Appendix B or 40 CFR part 75, Appendices A to I, incorporated by reference in s. NR 484.04 (21) and (27), and follow a quality control and quality assurance plan for the monitor which has been approved by the department.
NR 439.06(9)(b)(b) The owner or operator of a source shall use Method 22 in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), to determine compliance with a no visible emission requirement.
NR 439.06 HistoryHistory: Cr. Register, September, 1987, No. 381, eff. 10-1-87; cr. (3) (g), Register, April, 1988, No. 388, eff. 5-1-88; am. (intro.) (3) and (6) (a), cr. (3) (h), Register, February, 1990, No. 410, eff. 3-1-90; am. (intro.) and (2) (c), Register, May, 1992, No. 437, eff. 6-1-92; am. (3) (c), cr. (3) (i), Register, January, 1993, No. 445, eff. 2-1-93; am. (2) (a) and (3) (intro.), Register, May, 1993, No. 449, eff. 6-1-93; am. (intro.), (1), (4) (a), (6) (b), (6) (e), (7) (a), (8), (9) (a) 2., cr. (1m), Register, December, 1993, No. 456, eff. 1-1-94; am. (1), (1m), (2) (a), (b), (3) (a) to (d), (g), (i) 1., 2., (4) (a), (b), (5), (6) (a), (b), (7) (a), (b), (9) (a) 1., 2., (9) (b), Register, February, 1995, No. 470, eff. 3-1-95; am. (2) (b), Register, April, 1995, No. 472, eff. 5-1-95; cr. (3) (j), Register, June, 1995, No. 474, eff. 7-1-95; am. (3) (intro.) and (h), Register, November, 1999, No. 527, eff. 12-1-99; cr. (3) (am), Register, March, 2000, No. 531, eff. 4-1-00; CR. 02-146: am. (1) Register October 2003 No. 574, eff. 11-1-03; CR 08-102: am. (3) (j) Register July 2009 No. 643, eff. 8-1-09; CR 11-005: am. (3) (b) Register January 2012 No. 673, eff. 2-1-12; CR 15-077: r. (3) (i) Register July 2016 No. 727, eff. 8-1-16.
NR 439.07NR 439.07Methods and procedures for periodic compliance emission testing. The owner or operator of a source required to conduct emission testing under s. NR 439.075 shall comply with all applicable methods and procedures listed in this section.
NR 439.07(1)(1)General. All emission tests conducted for the purpose of determining compliance with an emission limitation under chs. NR 400 to 499 shall be performed according to the test methods established in 40 CFR part 60, Appendix A, 40 CFR part 61, Appendix B, and 40 CFR part 63, Appendix A, incorporated by reference in s. NR 484.04 (13), (23), and (25), or according to other test methods approved in writing by the department. The owner, operator or contractor responsible for emission testing shall follow the procedures in this section. Unless the department requires or approves the performance of a test at less than capacity, all compliance emission tests shall be performed with the equipment operating at capacity or as close to capacity as practicable.
NR 439.07(2)(2)Emission test notification and test plan submittal. The department shall be notified in writing at least 20 business days in advance of a compliance emission test, including initial certification tests and relative accuracy tests performed under s. NR 439.09, to provide the department an opportunity to have a representative present to witness the testing procedures. The notice shall provide a test plan which includes, but need not be limited to, the following: