NR 665.1035(3)(e)(e) Explanation for each period recorded under par. (d) of the cause for control device operating parameter exceeding the design value and the measures implemented to correct the control device operation.
NR 665.1035(3)(f)(f) For carbon adsorption systems operated subject to s. NR 665.1033 (7) or (8) (b), date when existing carbon in the control device is replaced with fresh carbon.
NR 665.1035(3)(g)(g) For carbon adsorption systems operated subject to s. NR 665.1033 (8) (a), a log that records all of the following:
NR 665.1035(3)(g)1.1. Date and time when control device is monitored for carbon breakthrough and the monitoring device reading.
NR 665.1035(3)(g)2.2. Date when existing carbon in the control device is replaced with fresh carbon.
NR 665.1035(3)(h)(h) Date of each control device startup and shutdown.
NR 665.1035(3)(i)(i) An owner or operator designating any components of a closed-vent system as unsafe to monitor pursuant to s. NR 665.1033 (14) shall record in a log that is kept in the facility operating record the identification of closed-vent system components that are designated as unsafe to monitor according to s. NR 665.1033 (14), an explanation for each closed-vent system component stating why the closed-vent system component is unsafe to monitor and the plan for monitoring each closed-vent system component.
NR 665.1035(3)(j)(j) When each leak is detected as specified in s. NR 665.1033 (11), record all of the following information:
NR 665.1035(3)(j)1.1. The instrument identification number, the closed-vent system component identification number and the operator name, initials or identification number.
NR 665.1035(3)(j)2.2. The date the leak was detected and the date of first attempt to repair the leak.
NR 665.1035(3)(j)3.3. The date of successful repair of the leak.
NR 665.1035(3)(j)4.4. Maximum instrument reading measured by Method 21 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11, after the leak is successfully repaired or determined to be nonrepairable.
NR 665.1035(3)(j)5.5. “Repair delayed” and the reason for the delay if a leak is not repaired within 15 calendar days after discovery of the leak.
NR 665.1035(3)(j)5.a.a. The owner or operator may develop a written procedure that identifies the conditions that justify a delay of repair. In those cases, reasons for delay of repair may be documented by citing the relevant sections of the written procedure.
NR 665.1035(3)(j)5.b.b. If delay of repair was caused by depletion of stocked parts, there shall be documentation that the spare parts were sufficiently stocked on-site before depletion and the reason for depletion.
NR 665.1035(4)(4)Maintain records of the monitoring, operating and inspection information required by sub. (3) (c) to (j) for at least 3 years following the date of each occurrence, measurement, maintenance, corrective action or record.
NR 665.1035(5)(5)For a control device other than a thermal vapor incinerator, catalytic vapor incinerator, flare, boiler, process heater, condenser or carbon adsorption system, record monitoring and inspection information indicating proper operation and maintenance of the control device in the facility operating record.
NR 665.1035(6)(6)Record up-to-date information and data used to determine whether or not a process vent is subject to s. NR 665.1032, including supporting documentation required by s. NR 665.1034 (4) (b) when application of the knowledge of the nature of the hazardous waste stream or the process by which it was produced is used, in a log that is kept in the facility operating record.
NR 665.1035 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
subch. BB of ch. NR 665Subchapter BB — Air Emission Standards for Equipment Leaks
NR 665.1050NR 665.1050Applicability.
NR 665.1050(1)(1)This subchapter applies to owners and operators of facilities that treat, store or dispose of hazardous wastes (except as provided in s. NR 665.0001).
NR 665.1050(2)(2)Except as provided in s. NR 665.1064 (11), this subchapter applies to equipment that contains or contacts hazardous wastes with organic concentrations of at least 10 percent by weight that are managed in one of the following:
NR 665.1050(2)(a)(a) A unit that is subject to the licensing requirements of ch. NR 670.
NR 665.1050(2)(b)(b) A unit (including a hazardous waste recycling unit) that is not exempt from licensing under s. NR 662.017 (i.e., a hazardous waste recycling unit that is not a “90-day” tank or container) and that is located at a hazardous waste management facility otherwise subject to the licensing requirements of ch. NR 670.
NR 665.1050(2)(c)(c) A unit that is exempt from licensing under s. NR 662.017 (i.e., a “90-day” tank or container) and is not a recycling unit under s. NR 661.0006.
NR 665.1050(3)(3)Each piece of equipment to which this subchapter applies shall be marked in such a manner that it can be distinguished readily from other pieces of equipment.
NR 665.1050(4)(4)Equipment that is in vacuum service is excluded from ss. NR 665.1052 to 665.1060 if it is identified as required in s. NR 665.1064 (7) (e).
NR 665.1050(5)(5)Equipment that contains or contacts hazardous waste with an organic concentration of at least 10 percent by weight for less than 300 hours per calendar year is excluded from ss. NR 665.1052 to 665.1060 if it is identified, as required in s. NR 665.1064 (7) (f).