NR 466.05NR 466.05 Standards: general. General provisions of ch. NR 460 apply to owners and operators of affected sources subject to this chapter as indicated in ch. NR 460 Appendix KK. NR 466.05 HistoryHistory: Cr. Register, March, 2000, No. 531, eff. 4-1-00. NR 466.06NR 466.06 Standards: publication rotogravure printing. NR 466.06(1)(1) Compliance dates. Each owner or operator of any publication rotogravure printing affected source that is subject to the requirements of this chapter shall comply with this section on and after the compliance dates as specified in s. NR 466.08. NR 466.06(2)(2) Emission limitation. The owner or operator of each publication rotogravure affected source shall limit organic HAP emissions to no more than 8% of the total volatile matter used each month. NR 466.06(3)(3) Compliance methods. The emission limitation in sub. (2) shall be achieved by any of the following methods: NR 466.06(3)(c)(c) A combination of capture and control technologies and substitution of materials. NR 466.06(4)(a)(a) Solvent recovery. Each owner or operator using a solvent recovery device to control emissions shall demonstrate compliance by showing that the HAP emission limitation is achieved by doing either of the following: NR 466.06(4)(a)1.1. Perform a liquid-liquid material balance for each month according to the following procedures: NR 466.06(4)(a)1.a.a. Measure the mass of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month. NR 466.06(4)(a)1.b.b. Determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month following the procedure in s. NR 466.09 (2) (a). NR 466.06(4)(a)1.c.c. Determine the volatile matter content, including water, of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month following the procedure in s. NR 466.09 (3) (a). NR 466.06(4)(a)1.d.d. Install, calibrate, maintain and operate, according to the manufacturer’s specifications, a device that indicates the cumulative amount of volatile matter recovered by the solvent recovery device on a monthly basis. The device shall be initially certified by the manufacturer to be accurate to within +2.0%. NR 466.06(4)(a)1.f.f. Calculate the overall effective organic HAP control efficiency (Re) for the month using Equation 1. For the purposes of this calculation, the mass fraction of organic HAP present in the recovered volatile matter is assumed to be equal to the mass fraction of organic HAP present in the volatile matter used. (Equation 1)
NR 466.06(4)(a)2.2. Use continuous emission monitors, conduct an initial performance test of capture efficiency, and continuously monitor a site specific operating parameter to assure capture efficiency as specified in the following procedures: NR 466.06(4)(a)2.a.a. Install continuous emission monitors to determine the total organic volatile matter mass flow rate at both the inlet to and the outlet from the control device, and calculate the percent efficiency (E) of the control device for each month. NR 466.06(4)(a)2.c.c. Calculate the overall effective organic HAP control efficiency (Re) achieved for each month using Equation 2. (Equation 2)
NR 466.06(4)(a)2.d.d. Install, calibrate, operate and maintain the instrumentation necessary to measure continuously the site-specific operating parameter established in accordance with s. NR 466.10 (6) whenever a publication rotogravure printing press is operated. NR 466.06(4)(a)2.e.e. Operate the capture device at an average value greater than, or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6) for each 3-hour period. NR 466.06(4)(b)(b) Oxidation. Each owner or operator using an oxidizer to control emissions shall demonstrate compliance by showing that the HAP emission limitation is achieved by doing either of the following: