NR 812.42(9)(a)3.3. Screens may not be replaced on driven point wells terminating in or extending through basements or below-grade crawl spaces. When a driven point well screen needs replacement, the driven point well shall be permanently filled and sealed according to the requirements of s. NR 812.26. Any replacement well shall meet the requirements for new wells in this chapter. NR 812.42(9)(a)4.4. Wells terminating in basements or below grade crawl spaces may remain in service if all of the following conditions are met: NR 812.42(9)(a)4.b.b. If the well is a driven point, the point was never replaced after April 10, 1953. NR 812.42(9)(a)4.e.e. The well and pump installation are in compliance with all other requirements of this chapter. NR 812.42(9)(b)(b) Wells in walkout basements. Wells terminating in walkout basements may remain in service if all of the following conditions are met: NR 812.42(9)(b)1.1. It is possible to walk directly outside from the walkout basement without walking upstairs or upslope. NR 812.42(9)(b)2.2. The surface of the ground around the outside exit door of the walkout basement slopes down away from the door. NR 812.42(9)(b)3.3. The well and pump installation are accessible for repair and removal. NR 812.42(9)(b)6.6. The well and pump installation are in compliance with all other requirements of this chapter. NR 812.42(9)(b)9.9. The well is sealed watertight where the well casing exits the basement floor. NR 812.42(10)(10) Driveway ramps. A well may terminate within a driveway ramp if the installation complies with the requirements for driveway ramps in s. NR 812.36 (3). NR 812.42(11)(a)(a) Pits and alcoves, noncompliant casing height or well deepening. Before extending any well casing pipe out of a pit or alcove, extending casing when the height is noncompliant, or deepening a well constructed by another individual, the well driller or the pump installer shall measure the well casing pipe depth to verify that the casing depth complies with the rules in effect at the time the well casing was installed including any special well casing depth area requirements or variances, if no confirmable well construction report can be found for the well. Well details, including location, well casing pipe depth, total well depth, distances to possible contaminant sources, and well owner information shall be entered on a form and submitted to the department in accordance with s. NR 812.10 (15). NR 812.42(11)(am)(am) Reconstruction. A well constructed in violation of the requirements in effect at the time of construction or a well constructed to meet the requirements in effect at the time of construction but not according to the construction requirements of ss. NR 812.09 to 812.15 may not be reconstructed. NR 812.42(11)(b)(b) Sample Faucet. When doing any pump work involving replacement of the pressure tank, or work involving the water supply piping inside the basement or building, the pump installer shall install sample faucets that meet the requirements specified in s. NR 812.34 if any are missing. The pump installer shall also replace any sample faucet that does not comply with the requirements of s. NR 812.34, including replacement of any threaded sample faucet with a sample faucet without threads. The pump installer or well owner may not file the threads off a noncomplying sample faucet. NR 812.42(11)(c)1.1. When doing any water well work or pump installing work that involves entry into a well located outside a building, the water well driller or pump installer shall extend the well casing pipe to at least: NR 812.42(11)(c)1.a.a. 12 inches above grade for any well that is less than 8 inches above grade and was installed before February 1, 1991. NR 812.42(11)(c)1.b.b. 12 inches above grade for any well that is less than 12 inches above grade and was installed on or after February 1, 1991. NR 812.42(11)(c)2.2. When the well casing height above grade does not comply with subd. 1. a. or b., the well driller or the pump installer shall measure the well casing pipe depth to verify that the well casing pipe depth complies with the rules in effect at the time that the well was constructed, if there is no confirmable well construction report available for the well. Well details, including location, well casing pipe depth, total well depth, distances to possible contaminant sources and well owner information shall be entered on a form and submitted to the department in accordance with s. NR 812.10 (15).