NR 440.76(12)(f)1.e.e. All 1-hour average load levels of your municipal waste combustion unit.
NR 440.76(12)(f)1.f.f. All 1-hour average flue gas temperatures at the inlet of the particulate matter control device.
NR 440.76(12)(f)2.2. ‘Average concentrations and percent reductions.’ You shall document the following 5 parameters:
NR 440.76(12)(f)2.a.a. All 24-hour daily block geometric average concentrations of sulfur dioxide emissions or average percent reductions of sulfur dioxide emissions.
NR 440.76(12)(f)2.b.b. For Class I municipal waste combustion units only, all 24-hour daily arithmetic average concentrations of nitrogen oxides emissions.
NR 440.76(12)(f)2.c.c. All 4-hour block or 24-hour daily block arithmetic average concentrations of carbon monoxide emissions.
NR 440.76(12)(f)2.d.d. All 4-hour block arithmetic average load levels of your municipal waste combustion unit.
NR 440.76(12)(f)2.e.e. All 4-hour block arithmetic average flue gas temperatures at the inlet of the particulate matter control device.
NR 440.76(12)(f)3.3. ‘Exceedances.’ You shall document the following 3 items:
NR 440.76(12)(f)3.a.a. Calendar dates whenever any of the 5 pollutant or parameter levels recorded in subd. 2. or the opacity level recorded in subd. 1. a. did not meet the emission limits or operating levels specified in this section.
NR 440.76(12)(f)3.b.b. Reasons you exceeded the applicable emission limits or operating levels.
NR 440.76(12)(f)3.c.c. Corrective actions you took, or are taking, to meet the emission limits or operating levels.
NR 440.76(12)(f)4.4. ‘Minimum data.’ You shall document the following 3 items:
NR 440.76(12)(f)4.a.a. Calendar dates for which you did not collect the minimum amount of data required under subs. (9) (h) and (11) (e). Record the dates for the following 5 types of pollutants and parameters:
1) Sulfur dioxide emissions.
2) For Class I municipal waste combustion units only, nitrogen oxides emissions.
3) Carbon monoxide emissions.
4) Load levels of your municipal waste combustion unit.
5) Temperatures of the flue gases at the inlet of the particulate matter control device.
NR 440.76(12)(f)4.b.b. Reasons you did not collect the minimum data.
NR 440.76(12)(f)4.c.c. Corrective actions you took, or are taking, to obtain the required amount of data.
NR 440.76(12)(f)5.5. ‘Exclusions.’ You shall document each time you have excluded data from your calculation of averages for any of the following 5 pollutants or parameters and the reasons the data were excluded:
NR 440.76(12)(f)5.a.a. Sulfur dioxide emissions.
NR 440.76(12)(f)5.b.b. For Class I municipal waste combustion units only, nitrogen oxides emissions.
NR 440.76(12)(f)5.c.c. Carbon monoxide emissions.
NR 440.76(12)(f)5.d.d. Load levels of your municipal waste combustion unit.
NR 440.76(12)(f)5.e.e. Temperatures of the flue gases at the inlet of the particulate matter control device.
NR 440.76(12)(f)6.6. ‘Drift and accuracy.’ You shall document the results of your daily drift tests and quarterly accuracy determinations according to Procedure 1 of 40 CFR part 60, Appendix F, incorporated by reference in s. NR 440.17 (1). Keep the records for the sulfur dioxide, nitrogen oxides for Class I municipal waste combustion units only, and carbon monoxide continuous emissions monitoring systems.
NR 440.76(12)(f)7.7. ‘The relationship between oxygen and carbon dioxide.’ If you choose to monitor carbon dioxide instead of oxygen as a diluent gas, you shall document the relationship between oxygen and carbon dioxide, as specified in sub. (9) (g).