NR 466.25(14)(f)2.2. The total mass of organic HAP emitted by the affected source based on material applied is no more than 0.04 kg of organic HAP per kg of material applied at an existing affected source and no more than 0.016 kg of organic HAP per kg of material applied at a new affected source. NR 466.25(14)(f)3.3. The total mass of organic HAP emitted by the affected source during the month is less than the calculated allowable organic HAP as determined using sub. (12). NR 466.25(14)(f)4.4. The total mass of organic HAP emitted by the affected source was not more than 5% of the total mass of organic HAP applied for the month at an existing affected source and no more than 2% of the total mass of organic HAP applied for the month at a new affected source. The total mass of organic HAP applied by the affected source in the month shall be determined using Equation 6 in sub. (4). NR 466.25(15)(15) Intermittently-controlled and never-controlled work stations. If you have been expressly referred to this subsection by sub. (14) (a) 2., (b) 2. b. or (c) 3. b. for calculation procedures to determine organic HAP emissions for your intermittently-controlled and never-controlled work stations, you shall do all of the following: NR 466.25(15)(a)(a) Determine the sum of the mass of all coating materials as-applied on intermittently-controlled work stations operating in bypass mode and the mass of all coating materials as-applied on never-controlled work stations during the month. NR 466.25(15)(b)(b) Determine the sum of the mass of all coating materials as-applied on intermittently-controlled work stations operating in a controlled mode and the mass of all coating materials applied on always-controlled work stations during the month. NR 466.25(15)(c)(c) For each web coating line or group of web coating lines for which you use the provisions of sub. (14) (a) 2. for liquid-liquid material balance compliance demonstration, calculate the organic HAP emitted during the month using Equation 14: where:
He is the total monthly organic HAP emitted, kg
p is the number of different coating materials applied in a month
MCi is the sum of the mass of coating material, i, as-applied on intermittently-controlled work stations operating in controlled mode and the mass of coating material, i, as-applied on always-controlled work stations, in a month, kg
Cahi is the monthly average, as-applied, organic HAP content of coating material, i, expressed as a mass fraction, kg/kg
Rv is the organic volatile matter collection and recovery efficiency, percent
MBi is the sum of the mass of coating material, i, as-applied on intermittently-controlled work stations operating in bypass mode and the mass of coating material, i, as-applied on never-controlled workstations, in a month, kg
Mvret is the mass of volatile matter retained in the coated web after curing or drying, or otherwise not emitted to the atmosphere, kg. The value of this term will be zero in all cases except where you choose to take into account the volatile matter retained in the coated web or otherwise not emitted to the atmosphere for the compliance demonstration procedures in this section.
NR 466.25(15)(d)(d) For each web coating line or group of web coating lines for which you use the provisions of sub. (14) (b) 2. b. or (c) 3. b. on using a performance test to determine capture efficiency and control device efficiency, calculate the organic HAP emitted during the month using Equation 15: where:
He is the total monthly organic HAP emitted, kg
p is the number of different coating materials applied in a month
MCi is the sum of the mass of coating material, i, as-applied on intermittently-controlled work stations operating in controlled mode and the mass of coating material, i, as-applied on always-controlled work stations, in a month, kg
Cahi is the monthly average, as-applied, organic HAP content of coating material, i, expressed as a mass fraction, kg/kg
R is the overall organic HAP control efficiency, percent
MBi is the sum of the mass of coating material, i, as-applied on intermittently-controlled work stations operating in bypass mode and the mass of coating material, i, as-applied on never-controlled work stations, in a month, kg
Mvret is the mass of volatile matter retained in the coated web after curing or drying, or otherwise not emitted to the atmosphere, kg. The value of this term will be zero in all cases except where you choose to take into account the volatile matter retained in the coated web or otherwise not emitted to the atmosphere for the compliance demonstration procedures in this section.
NR 466.25(16)(16) Always-controlled work stations with more than one capture and control system. If you operate more than one capture system or more than one control device and only have always-controlled work stations, you are in compliance with the emission standards in s. NR 466.23 (1) (b) 1. for the month if for each web coating line or group of web coating lines controlled by a common control device you satisfy one of the following: NR 466.25(16)(a)(a) The volatile matter collection and recovery efficiency as determined by sub. (9) (a) 1., 3., 5. and 6. is at least 95% at an existing affected source and at least 98% at a new affected source. NR 466.25(16)(b)(b) The overall organic HAP control efficiency as determined by sub. (9) (b) 1. to 4. for each web coating line or group of web coating lines served by that control device and a common capture system is at least 95% at an existing affected source and at least 98% at a new affected source.