NR 466.25(14)(b)2.b.b. Subsections (9) (b) 1. to 3. and 6. and (15) if the web coating lines served by the capture and control system have one or more never-controlled or intermittently-controlled work stations. NR 466.25(14)(c)(c) Oxidizer. To demonstrate compliance through performance tests of capture efficiency and control device efficiency, continuous monitoring of capture system and CPMS for control device operating parameters for each oxidizer used to control emissions from one or more web coating lines, you shall do all of the following: NR 466.25(14)(c)2.2. For each capture system delivering emissions to the oxidizer, monitor the operating parameter established in accordance with s. NR 466.24 (2) (f) to ensure capture efficiency. NR 466.25(14)(c)3.3. Determine the organic HAP emissions for the web coating lines served by each capture system delivering emissions to that oxidizer in accordance with one of the following: NR 466.25(14)(c)3.a.a. In accordance with sub. (11) (a) 1. to 4. if the web coating lines served by the capture and control system have only always-controlled work stations. NR 466.25(14)(c)3.b.b. In accordance with sub. (11) (a) 1. to 3. and 5. and sub. (15) if the web coating lines served by the capture and control system have one or more never-controlled or intermittently-controlled work stations. NR 466.25(14)(d)(d) Uncontrolled coating lines. If you own or operate one or more uncontrolled web coating lines, you shall determine the organic HAP applied on the web coating lines using Equation 6 in sub. (4). The organic HAP emitted from an uncontrolled web coating line is equal to the organic HAP applied on the web coating line. NR 466.25(14)(e)(e) Conversion of information. Convert the information obtained under pars. (a) to (d) into the units of the selected compliance option using the calculation procedures specified in subds. 1. to 4. NR 466.25(14)(e)1.1. Calculate the organic HAP emissions for the affected source for the month by summing all organic HAP emissions calculated according to pars. (a), (b) 2., (c) 3. and (d). NR 466.25(14)(e)2.2. If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied or emission of less than the calculated allowable organic HAP, you shall determine the coating solids content of each coating material applied during the month following the procedure in s. NR 466.24 (3) (d). NR 466.25(14)(e)3.3. Calculate the organic HAP emission rate based on coating solids applied for each month using Equation 9 in sub. (9) (a) 8. NR 466.25(14)(f)(f) Compliance. You are in compliance with the emission standards in s. NR 466.23 (1) (b) for the month if all operating parameters required to be monitored under pars. (a) to (c) were maintained at the values established under s. NR 466.24 (2) and (3), and you satisfy one of the following: NR 466.25(14)(f)1.1. The total mass of organic HAP emitted by the affected source based on coating solids applied is no more than 0.20 kg of organic HAP per kg of coating solids applied at an existing affected source and no more than 0.08 kg of organic HAP per kg of coating solids applied at a new affected source. NR 466.25(14)(f)2.2. The total mass of organic HAP emitted by the affected source based on material applied is no more than 0.04 kg of organic HAP per kg of material applied at an existing affected source and no more than 0.016 kg of organic HAP per kg of material applied at a new affected source. NR 466.25(14)(f)3.3. The total mass of organic HAP emitted by the affected source during the month is less than the calculated allowable organic HAP as determined using sub. (12). NR 466.25(14)(f)4.4. The total mass of organic HAP emitted by the affected source was not more than 5% of the total mass of organic HAP applied for the month at an existing affected source and no more than 2% of the total mass of organic HAP applied for the month at a new affected source. The total mass of organic HAP applied by the affected source in the month shall be determined using Equation 6 in sub. (4). NR 466.25(15)(15) Intermittently-controlled and never-controlled work stations. If you have been expressly referred to this subsection by sub. (14) (a) 2., (b) 2. b. or (c) 3. b. for calculation procedures to determine organic HAP emissions for your intermittently-controlled and never-controlled work stations, you shall do all of the following: NR 466.25(15)(a)(a) Determine the sum of the mass of all coating materials as-applied on intermittently-controlled work stations operating in bypass mode and the mass of all coating materials as-applied on never-controlled work stations during the month. NR 466.25(15)(b)(b) Determine the sum of the mass of all coating materials as-applied on intermittently-controlled work stations operating in a controlled mode and the mass of all coating materials applied on always-controlled work stations during the month. NR 466.25(15)(c)(c) For each web coating line or group of web coating lines for which you use the provisions of sub. (14) (a) 2. for liquid-liquid material balance compliance demonstration, calculate the organic HAP emitted during the month using Equation 14: where:
He is the total monthly organic HAP emitted, kg
p is the number of different coating materials applied in a month
MCi is the sum of the mass of coating material, i, as-applied on intermittently-controlled work stations operating in controlled mode and the mass of coating material, i, as-applied on always-controlled work stations, in a month, kg
Cahi is the monthly average, as-applied, organic HAP content of coating material, i, expressed as a mass fraction, kg/kg