where:
HCSR is the mass of organic HAP emissions reduction for the coating operation controlled by the solvent recovery system using a liquid-liquid material balance during the compliance period, kg
AI is the total mass of organic HAP in the coatings used in the coating operation controlled by the solvent recovery system, kg, calculated using Equation 1A in par. (f)
BI is the total mass of organic HAP in the thinners used in the coating operation controlled by the solvent recovery system, kg, calculated using Equation 1B in par. (f)
CI is the total mass of organic HAP in the cleaning materials used in the coating operation controlled by the solvent recovery system, kg, calculated using Equation 1C in par. (f)
RV is the volatile organic matter collection and recovery efficiency of the solvent recovery system, percent, from Equation 2 in subd. 6.
NR 465.28(2)(h)(h) Determine the total volume of coating solids used, liters, which is the combined volume of coating solids for all the coatings used during the compliance period, using Equation 2 in s. NR 465.27 (2) (f). NR 465.28(2)(i)(i) Determine the organic HAP emission rate to the atmosphere, kg organic HAP per liter coating solids used during the compliance period, using the following equation: (Equation 4)
where:
HHAP is the organic HAP emission rate to the atmosphere during the compliance period, kg organic HAP per liter coating solids used
He is the total mass of organic HAP emissions before add-on controls from all the coatings, thinners and cleaning materials used during the compliance period, kg, determined according to par. (d)
HC,i is the total mass of organic HAP emissions reduction for controlled coating operation, i, during the compliance period, kg, from Equation 1 in par. (f)
HCSR,j is the total mass of organic HAP emissions reduction for controlled coating operation, j, during the compliance period, kg, from Equation 3 in par. (g)
Vst is the total volume of coating solids used during the compliance period, liters, from Equation 2 in s. NR 465.27 (2) (f) q is the number of controlled coating operations except those controlled with a solvent recovery system
r is the number of coating operations controlled with a solvent recovery system
NR 465.28(2)(j)(j) Demonstrate initial compliance with the emission limit, by ensuring that the organic HAP emission rate calculated using Equation 4 in par. (i), is less than or equal to the applicable emission limit in s. NR 465.25 (3). Keep all records as required by s. NR 465.25 (3) and (4). As part of the notification of compliance status required by s. NR 465.25 (1), identify the coating operation or operations for which you used the emission rate with add-on controls option and submit a statement that the coating operation or operations was or were in compliance with the emission limitations during the initial compliance period because the organic HAP emission rate was less than or equal to the applicable emission limit in s. NR 465.23 (1), and you achieved the operating limits and the work practice standards required by s. NR 465.23 (3) and (4) respectively. NR 465.28(4)(4) How do I demonstrate continuous compliance with the emission limitations?. NR 465.28(4)(a)(a) To demonstrate continuous compliance with the applicable emission limit in s. NR 465.23 (1), the organic HAP emission rate for each compliance period determined according to the procedures in sub. (2) shall be equal to or less than the applicable emission limit in s. NR 465.23 (1). Each month following the initial compliance period described in sub. (1) is a compliance period. NR 465.28(4)(b)(b) If the organic HAP emission rate for any compliance period exceeded the applicable emission limit in s. NR 465.23 (1), this is a deviation from the emission limitation for that compliance period and shall be reported as specified in s. NR 465.25 (1) (b) 6. and (2) (g). NR 465.28(4)(c)(c) You shall demonstrate continuous compliance with each operating limit required by s. NR 465.23 (3) that applies to you as specified in Table 1 of this subchapter, and shall do the following as applicable: NR 465.28(4)(c)2.2. If an operating parameter deviates from the operating limit specified in Table 1 of this subchapter, assume that the emission capture system and add-on control device were achieving zero efficiency during the time period of the deviation. For the purposes of completing the compliance calculations specified in sub. (2), treat the materials used during a deviation on a controlled coating operation as if they were used on an uncontrolled coating operation for the time period of the deviation. You may not include those materials in the calculation of organic HAP emissions reductions in Equation 1 in sub. (2) (f). NR 465.28(4)(d)(d) You shall meet the requirements for bypass lines in sub. (9) (b). You shall report it as a deviation, as specified in s. NR 465.25 (1) (b) 6. and (2) (g), if any bypass line is opened and emissions are diverted to the atmosphere when the coating operation is running. For the purposes of completing the compliance calculations specified in sub. (2), you shall treat the materials used during a deviation on a controlled coating operation as if they were used on an uncontrolled coating operation for the time period of the deviation. You may not include those materials in the calculation of organic HAP emissions reductions in Equation 1 in sub. (2) (f). NR 465.28(4)(e)(e) You shall demonstrate continuous compliance with the work practice standards in s. NR 465.23 (4). You shall report it as a deviation from the work practice standards, as specified in s. NR 465.25 (1) (b) 6. and (2) (g), if you did not develop a work practice plan, did not implement the plan, or you did not keep the records required by s. NR 465.25 (3) (k) 9. NR 465.28(4)(f)(f) As part of each semiannual compliance report required in s. NR 465.25 (2), you shall submit a statement that you were in compliance with the emission limitations during the reporting period because the organic HAP emission rate for each compliance period was less than or equal to the applicable emission limit in s. NR 465.23 (1), and you achieved the operating limits and the work practice standards required by s. NR 465.23 (3) and (4), respectively, during each compliance period. NR 465.28(4)(g)(g) During periods of startup, shutdown and malfunction of the emission capture system, add-on control device or coating operation that may affect emission capture or control device efficiency, you shall operate in accordance with the SSMP required by s. NR 465.24 (1) (d).