PSC 136.06(3)(h)(h) Side walls. Where no insulation exists in accessible outside walls, side wall insulation of R-11 shall be installed.
PSC 136.06(3)(i)(i) Ventilation. A free ventilating area of not less than 1/300 of the horizontal area shall be installed above ceiling or attic insulation.
PSC 136.06 NoteNote: One-half of venting near the eaves and the other half near the top of the roof is recommended. Where no vapor barrier is present, a free ventilating area of not less than 1/150 of the horizontal area is recommended.
PSC 136.06(3)(j)(j) Substituted standards. For existing residential structures unable to meet the conversion standards required by this section, other methods of energy conservation may be substituted if the energy savings are equivalent. Substitutions shall be based on heat loss calculations performed by the utility.
PSC 136.06 HistoryHistory: Cr. Register, February, 1985, No. 350, eff. 3-1-85.
PSC 136.10PSC 136.10Disconnection or refusal of service. Gas or electric service may be disconnected or refused for failure to comply with the regulations contained in this chapter as specified in ss. PSC 113.0301 and 134.062. If a customer has converted without notifying the appropriate utility and has failed to comply with the requirements of s. PSC 136.06, the utility may allow the customer not more than 6 months to comply with those requirements.