State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES.
Not certified. Does not meet DNR particulate emission standards.
IT IS AGAINST THE LAW TO OPERATE THIS WOOD HEATER.
NR 440.642(7)(g)2.2. If the test conducted under sub. (4) (n) indicates that the facility does meet applicable emissions limits: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Not certified. Meets DNR particulate emission standards.
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES.
Not certified. Not tested. Not approved for sale.
IT IS AGAINST THE LAW TO OPERATE THIS WOOD HEATER.
NR 440.642(7)(h)(h) For affected facilities equipped with catalytic combustors, the following statement shall appear on the permanent label: This wood heater contains a catalytic combustor, which needs periodic inspection and replacement for proper operation. Consult owner’s manual for further information. It is against the law to operate this wood heater in a manner inconsistent with operating instructions in the owner’s manual or if the catalytic element is deactivated or removed.
NR 440.642(7)(i)(i) An affected facility permanently labeled under par. (b) shall have attached to it a temporary label that shall contain only the following: NR 440.642(7)(i)1.1. A statement indicating the compliance status of the model. The statement shall be one of the statements provided in 40 CFR part 60, Appendix I, Section 2.2.1, incorporated by reference in s. NR 440.17. Instructions on the statement to select are provided in 40 CFR part 60 in Appendix I, incorporated by reference in s. NR 440.17. NR 440.642(7)(i)2.2. A graphic presentation of the composite particulate matter emission rate as determined in the certification test. The method for presenting this information is provided in 40 CFR part 60, Appendix I, Section 2.2.2, incorporated by reference in s. NR 440.17. NR 440.642(7)(i)3.3. A graphic presentation of the overall thermal efficiency of the model. The method for presenting this information is provided in 40 CFR part 60, Appendix I, Section 2.2.3, incorporated by reference in s. NR 440.17. At the discretion of the manufacturer, either the actual measured efficiency of the model or its estimated efficiency may be used for purposes of this paragraph. The actual efficiency is the efficiency measured in tests conducted pursuant to 40 CFR 670.534 (d). The estimated efficiency shall be 72% if the model is catalyst-equipped and 63% if the model is not catalyst equipped, and 78% if the model is designed to burn wood pellets for fuel. NR 440.642(7)(i)4.4. A numerical expression of the heat output range of the unit, in British thermal units per hour (Btu/hr) rounded to the nearest 100 Btu/hr. NR 440.642(7)(i)4.a.a. If the manufacturer elects to report the overall efficiency of the model based on test results pursuant to subd. 3., the manufacturer shall report the heat output range measured during the efficiency test. If an accessory device is used in the certification test to achieve any low burn rate criterion specified in this section, and if this accessory device is not sold as a part of the wood heater, the heat output range shall be determined using the formula in subd. 4. b. based upon the lowest sustainable burn rate achieved without the accessory device. NR 440.642(7)(i)4.b.b. If the manufacturer elects to use the estimated efficiency as provided in subd. 3., the manufacturer shall estimate the heat output of the model as follows: where:
HOE is the estimated heat output in Btu/hr
HV is the heating value of fuel, 19,140 Btu/kg (8,700 Btu/lb)
BR is the burn rate of dry test fuel, kg/hr (lb/hr)
NR 440.642(7)(i)5.5. Statements regarding the importance of operation and maintenance. Instructions regarding which statements shall be used are provided in 40 CFR part 60, Appendix I, Section 2., incorporated by reference in s. NR 440.17; and