NR 440.62(7)(b)1.1. A weather proof and readily visible identification, marked with the equipment identification number, shall be attached to the leaking equipment. NR 440.62(7)(b)2.2. The identification on a value may be removed after it has been monitored for 2 successive months as specified in sub. (3) (g) 3. and no leak has been detected during those 2 months. NR 440.62(7)(b)3.3. The identification on equipment except on valve may be removed after it has been repaired. NR 440.62(7)(c)(c) When each leak is detected as specified in subs. (3) (b), (c), (g), (h) and (4) (b) the following information shall be recorded in a log and shall be kept for 2 years in a readily accessible location: NR 440.62(7)(c)1.1. The instrument and operator identification numbers and the equipment identification number. NR 440.62(7)(c)2.2. The date the leak was detected and the dates each attempt to repair the leak. NR 440.62(7)(c)4.4. “Above 10,000” if the maximum instrument reading measured by the methods specified in sub. (6) (a) after each repair attempt is equal to or greater than 10,000 ppm. NR 440.62(7)(c)5.5. “Repair delayed” and the reason for the delay if a leak is not repaired within 15 calendar days after discovery of the leak. NR 440.62(7)(c)6.6. The signature of the owner or operator (or designate) whose decision it was that repair could not be affected without a process shutdown. NR 440.62(7)(c)7.7. The expected date of successful repair of the leak if a leak is not repaired within 15 days. NR 440.62(7)(c)8.8. Dates of process unit shutdown that occur while the equipment is unrepaired. NR 440.62(7)(d)(d) The following information pertaining to the design requirements for closed vent systems and control devices described in sub. (3) (j) shall be recorded and kept in a readily accessible location: NR 440.62(7)(d)1.1. Detailed schematics, design specifications and piping and instrumentation diagrams. NR 440.62(7)(d)2.2. The dates and descriptions of any changes in the design specifications. NR 440.62(7)(d)3.3. A description of the parameter or parameters monitored as required in sub. (3) (j) 5., to ensure that control devices are operated and maintained in conformance with their design and an explanation of why that parameter (or parameters) was selected for the monitoring. NR 440.62(7)(d)4.4. Periods when the closed vent systems and control devices required in sub. (3) (b), (c), (d) and (e) are not operated as designed, including periods when a flare pilot light does not have a flame. NR 440.62(7)(e)(e) The following information pertaining to all equipment subject to the requirements in sub. (3) (a) to (j) shall be recorded in a log that is kept in a readily accessible location: NR 440.62(7)(e)1.1. A list of identification numbers for equipment subject to the requirements of this section. NR 440.62(7)(e)3.3. A list of equipment identification numbers for pressure relief devices required to comply with sub. (3) (d). NR 440.62(7)(e)4.c.c. The maximum instrument reading measured at the equipment during each compliance test.