NR 670.019(3)(f)2.2. Waste feed rate.
NR 670.019(3)(f)3.3. Combustion zone temperature.
NR 670.019(3)(f)4.4. Indication of combustion gas velocity.
NR 670.019(3)(f)5.5. Expected stack gas volume, flow rate and temperature.
NR 670.019(3)(f)6.6. Computed residence time for waste in the combustion zone.
NR 670.019(3)(f)7.7. Expected hydrochloric acid removal efficiency.
NR 670.019(3)(f)8.8. Expected fugitive emissions and their control procedures.
NR 670.019(3)(f)9.9. Proposed waste feed cut-off limits based on the identified significant operating parameters.
NR 670.019(3)(g)(g) Supplemental information as the department finds necessary to achieve the purposes of this subsection.
NR 670.019(3)(h)(h) Waste analysis data, including that submitted in sub. (3) (a), sufficient to allow the department to specify in the license those principal organic hazardous constituents (license POHCs) for which destruction and removal efficiencies will be required.
NR 670.019(4)(4)The department shall approve a license application without a trial burn if the department finds that all of the following apply:
NR 670.019(4)(a)(a) The wastes are sufficiently similar.
NR 670.019(4)(b)(b) The incinerator units are sufficiently similar, and the data from other trial burns are adequate to specify (under s. NR 664.0345) operating conditions that will ensure that the performance standards in s. NR 664.0343 will be met by the incinerator.
NR 670.019(5)(5)When an owner or operator of a hazardous waste incineration unit becomes subject to hazardous waste licensing requirements after October 12, 2005, or when an owner or operator demonstrates compliance with the air emission standards and limitations in 40 CFR part 63, subpart EEE (for instance, by conducting a comprehensive performance test and submitting a notification of compliance under 40 CFR 63.1207 (j) and 63.1210 (d) documenting compliance with 40 CFR part 63, subpart EEE), the requirements of this section do not apply, except those provisions the department determines are necessary to ensure compliance with s. NR 664.0345 (1) and (3) if the owner or operator elects to comply with s. NR 670.235 (1) (a) 1. to minimize emissions of toxic compounds from startup, shutdown and malfunction events. Nevertheless, the department may apply the rules in this section, on a case-by-case basis, for purposes of information collection according to ss. NR 670.010 (11) and 670.032 (2) (b).
NR 670.019 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 16-007: am. (3) (a) 3., 4., (5) Register July 2017 No. 739, eff. 8-1-17; correction in (5) made under s. 35.17, Stats., Register July 2017 No. 739; CR 19-082: am. (1) (b), (d) Register August 2020 No. 776, eff. 9-1-20
NR 670.021NR 670.021Specific feasibility and plan of operation report information requirements for landfills. Except as otherwise provided in s. NR 664.0001, owners and operators of facilities that dispose of hazardous waste in landfills shall provide all of the following additional information:
NR 670.021(1)(1)A list of the hazardous wastes placed or to be placed in each landfill or landfill cell.
NR 670.021(2)(2)Detailed plans and an engineering report describing how the landfill is designed and is or will be constructed, operated and maintained to meet ss. NR 664.0019, 664.0301, 664.0302 and 664.0303, addressing all of the following items:
NR 670.021(2)(a)(a)
NR 670.021(2)(a)1.1. The liner system (except for an existing portion of a landfill), if the landfill shall meet s. NR 664.0301 (1). If an exemption from the requirement for a liner is sought as provided by s. NR 664.0301 (2), submit detailed plans, and engineering and hydrogeological reports, as appropriate, describing alternate designs and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous constituents into the groundwater or surface water at any future time.
NR 670.021(2)(a)2.2. The double liner and leak (leachate) detection, collection and removal system, if the landfill shall meet s. NR 664.0301 (3). If an exemption from the requirements for double liners and a leak detection, collection and removal system or alternative design is sought as provided by s. NR 664.0301 (4), (5) or (6), submit appropriate information.
NR 670.021(2)(a)3.3. If the leak detection system is located in a saturated zone, submit detailed plans and an engineering report explaining the leak detection system design and operation, and the location of the saturated zone in relation to the leak detection system.
NR 670.021(2)(a)4.4. The construction quality assurance (CQA) plan if required under s. NR 664.0019.
NR 670.021(2)(a)5.5. Proposed action leakage rate, with rationale, if required under s. NR 664.0302, and response action plan, if required under s. NR 664.0303.
NR 670.021(2)(b)(b) Control of run-on.
NR 670.021(2)(c)(c) Control of run-off.
NR 670.021(2)(d)(d) Management of collection and holding facilities associated with run-on and run-off control systems.
NR 670.021(2)(e)(e) Control of wind dispersal of particulate matter, where applicable.
NR 670.021(3)(3)A description of how each landfill, including the double liner system, leachate collection and removal system, leak detection system, cover system and appurtenances for control of run-on and run-off, will be inspected in order to meet s. NR 664.0303 (1), (2) and (3). This information shall be included in the inspection plan submitted under s. NR 670.014 (2) (e).