ATCP 76.12(3)(c)(c) Restriction of patrons. Patrons shall not be in the pool when chemicals are added directly into the pool basin. P ATCP 76.12(4)(a)(a) Smoking. Smoking by anyone handling chemicals or by anyone within the immediate vicinity of chemicals being mixed is prohibited. P ATCP 76.12(4)(b)1.1. For each chemical used, a safety data sheet shall be readily accessible to staff and the department or its agent. Pf ATCP 76.12 NoteNote: For example, the operator may keep the safety data sheet in a binder or on a computer as long as the operator or designated representative has immediate access to the information without leaving the pool area.
ATCP 76.12(4)(b)2.2. A paper back-up of the safety data sheet shall be available for rapid access in the case of a power outage or other emergency.Pf ATCP 76.12(4)(b)3.3. Staff shall be trained in the use of the safety data sheet and where they are located. Pf ATCP 76.12 HistoryHistory: CR 22-021: cr. Register June 2023 No. 810, eff. 9-24-23. ATCP 76.13ATCP 76.13 Chemical feeders and filter aid equipment. ATCP 76.13(1)(1) General. Chemical feeders and filter aid equipment shall be all of the following: ATCP 76.13(1)(a)(a) Installed. Installed according to the manufacturer’s directions. ATCP 76.13(1)(b)(b) Used. Chemical feeders shall only be used with the disinfectant or sanitizer recommended by the manufacturer and be all of the following: Pf ATCP 76.13(1)(c)(c) Interlocked. All recirculation systems shall be equipped with a chemical feed interlock pursuant to s. SPS 390.17 (2) (c) and (d), as enforced by the Wisconsin department of safety and professional services. P ATCP 76.13(1)(c)1.a.a. If power to the recirculation pump is interrupted, the chemical feed stops. Pf ATCP 76.13(1)(c)1.b.b. Except as provided in subd. 5., if flow in the recirculation system is interrupted, the chemical feeds stops. Pf ATCP 76.13(1)(c)2.2. The operator or their designee shall demonstrate knowledge to the department or its agent on the pool’s interlock system in all the following areas: ATCP 76.13(1)(c)2.a.a. Describes the location of chemical feed connections and system flow sensing interlocks in the recirculation system. P ATCP 76.13(1)(c)2.e.e. Describes what safety measures that must be employed during monthly testing. P ATCP 76.13(1)(c)3.3. Once monthly, challenge testing of the chemical feeder system shall be conducted to assess the interlock pursuant to subd. 1. P ATCP 76.13(1)(c)4.4. A log of the monthly test shall be kept and meet all of the following: ATCP 76.13(1)(c)4.a.a. Documented with the date, results, and the name of the person performing the test. P