NR 664.1087(3)(e)3.3. For a performance test conducted to meet subd. 1., use the test methods and procedures in s. NR 664.1034 (3) (a) to (d).
NR 664.1087(3)(e)4.4. For a design analysis conducted to meet subd. 1., meet the requirements in s. NR 664.1035 (2) (d) 3.
NR 664.1087(3)(e)5.5. Demonstrate that a carbon adsorption system achieves the performance requirements of par. (a) based on the total quantity of organics vented to the atmosphere from all carbon adsorption system equipment that is used for organic adsorption, organic desorption or carbon regeneration, organic recovery and carbon disposal.
NR 664.1087(3)(f)(f) If the owner or operator and the department do not agree on a demonstration of control device performance using a design analysis, resolve the disagreement using the results of a performance test performed by the owner or operator according to par. (e) 3. The department may choose to have an authorized representative observe the performance test.
NR 664.1087(3)(g)(g) Inspect and monitor the closed-vent system and control device according to s. NR 664.1033 (6) (b) and (12). Inspect the readings from each monitoring device required by s. NR 664.1033 (6) (b) at least once each operating day to check control device operation. Immediately implement any necessary corrective measures to ensure the control device is operated in compliance with this section.
NR 664.1087 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 664.1088NR 664.1088Inspection and monitoring requirements.
NR 664.1088(1)(1)The owner or operator shall inspect and monitor air emission control equipment used to comply with this subchapter according to the applicable requirements in ss. NR 664.1084 to 664.1087.
NR 664.1088(2)(2)The owner or operator shall develop and implement a written plan and schedule to perform the inspections and monitoring required by sub. (1). The owner or operator shall incorporate this plan and schedule into the facility inspection plan required under s. NR 664.0015.
NR 664.1088 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 664.1089NR 664.1089Recordkeeping requirements.
NR 664.1089(1)(1)Each owner or operator of a facility subject to requirements of this subchapter shall record and maintain the information specified in subs. (2) to (10), as applicable to the facility. Except for air emission control equipment design documentation and information required by subs. (9) and (10), maintain records required by this section in the operating record for a minimum of 3 years. Maintain air emission control equipment design documentation in the operating record until the air emission control equipment is replaced or otherwise no longer in service. Maintain information required by subs. (9) and (10) in the operating record for as long as the waste management unit is not using air emission controls specified in ss. NR 664.1084 to 664.1087 according to the conditions in s. NR 664.1080 (4) or (2) (g), respectively.
NR 664.1089(2)(2)The owner or operator of a tank using air emission controls according to s. NR 664.1084 shall prepare and maintain records for the tank that include all of the following information:
NR 664.1089(2)(a)(a) For each tank using air emission controls according to s. NR 664.1084, record all of the following:
NR 664.1089(2)(a)1.1. A tank identification number (or other unique identification description selected by the owner or operator).
NR 664.1089(2)(a)2.2. A record for each inspection required by s. NR 664.1084 that includes all of the following information:
NR 664.1089(2)(a)2.a.a. Date inspection was conducted.
NR 664.1089(2)(a)2.b.b. For each defect detected during the inspection, the location of the defect, a description of the defect, the date of detection and corrective action taken to repair the defect. In the event that repair of the defect is delayed according to s. NR 664.1084, also record the reason for the delay and the date that completion of repair of the defect is expected.
NR 664.1089(2)(b)(b) In addition to the information required by par. (a), record the following information, as applicable to the tank:
NR 664.1089(2)(b)1.1. If using a fixed roof to comply with the Tank Level 1 control requirements in s. NR 664.1084 (3), prepare and maintain records for each determination for the maximum organic vapor pressure of the hazardous waste in the tank performed according to s. NR 664.1084 (3). The records shall include the date and time the samples were collected, the analysis method used and the analysis results.
NR 664.1089(2)(b)2.2. If using an internal floating roof to comply with the Tank Level 2 control requirements in s. NR 664.1084 (5), prepare and maintain documentation describing the floating roof design.
NR 664.1089(2)(b)3.3. If using an external floating roof to comply with the Tank Level 2 control requirements in s. NR 664.1084 (6), prepare and maintain all of the following records:
NR 664.1089(2)(b)3.a.a. Documentation describing the floating roof design and the dimensions of the tank.
NR 664.1089(2)(b)3.b.b. Records for each seal gap inspection required by s. NR 664.1084 (6) (c) describing the results of the seal gap measurements. The records shall include the date that the measurements were performed, the raw data obtained for the measurements and the calculations of the total gap surface area. In the event that the seal gap measurements do not conform to the specifications in s. NR 664.1084 (6) (a), the records shall include a description of the repairs that were made, the date the repairs were made and the date the tank was emptied, if necessary.
NR 664.1089(2)(b)4.4. If using an enclosure to comply with the Tank Level 2 control requirements in s. NR 664.1084 (9), prepare and maintain all of the following records:
NR 664.1089(2)(b)4.a.a. Records for the most recent set of calculations and measurements performed by the owner or operator to verify that the enclosure meets the criteria for a permanent total enclosure in Method 204—“Criteria for and Verification of a Permanent or Temporary Total Enclosure” in appendix M of 40 CFR part 51, incorporated by reference in s. NR 660.11.
NR 664.1089(2)(b)4.b.b. Records required for the closed-vent system and control device according to sub. (5).
NR 664.1089(3)(3)The owner or operator of a surface impoundment using air emission controls according to s. NR 664.1085 shall prepare and maintain records for the surface impoundment that include all of the following information:
NR 664.1089(3)(a)(a) A surface impoundment identification number (or other unique identification description selected by the owner or operator).