NR 439.075(2)(c)(c) Except as provided in sub. (4), the owner or operator of a source identified in this paragraph which is subject to the requirements of ch. NR 440 shall perform compliance emission testing for the following air contaminants according to the testing schedules in sub. (3).
NR 439.075(2)(c)1.1. Compliance emission testing for particulate matter is required for the following:
NR 439.075(2)(c)1.a.a. Fossil fuel fired steam generators subject to s. NR 440.19 or 440.20.
NR 439.075(2)(c)1.b.b. Incinerators subject to s. NR 440.21.
NR 439.075(2)(c)1.c.c. Kilns at Portland cement plants subject to s. NR 440.22.
NR 439.075(2)(c)1.d.d. Dryers at asphalt concrete plants subject to s. NR 440.25 with a rated capacity of 250 tons per hour or more at 5% moisture removal.
NR 439.075(2)(c)1.e.e. Fluid catalytic cracking unit catalyst regenerators and fuel gas combustion devices at petroleum refineries subject to s. NR 440.26.
NR 439.075(2)(c)1.f.f. Pot, cupola and reverberatory furnaces at secondary lead smelters subject to s. NR 440.29.
NR 439.075(2)(c)1.g.g. Cupola, electric arc and reverberatory furnaces at secondary brass and bronze ingot production plants subject to s. NR 440.30.
NR 439.075(2)(c)1.h.h. Basic oxygen process furnaces at iron and steel plants subject to s. NR 440.31.
NR 439.075(2)(c)1.i.i. Incinerators at sewage treatment plants subject to s. NR 440.32.
NR 439.075(2)(c)1.j.j. Dryers at primary copper smelters subject to s. NR 440.33.
NR 439.075(2)(c)1.k.k. Sintering machines at primary zinc smelters subject to s. NR 440.34.
NR 439.075(2)(c)1.L.L. Blast furnaces, dross reverberatory furnaces and sintering machines at primary lead smelters subject to s. NR 440.35.
NR 439.075(2)(c)1.m.m. Thermal dryers and pneumatic coal cleaning equipment at coal preparation plants subject to s. NR 440.42.
NR 439.075(2)(c)1.n.n. Electric arc furnaces and dust handling equipment at ferroalloy production facilities subject to s. NR 440.43.
NR 439.075(2)(c)1.o.o. Electric arc furnaces at steel plants subject to s. NR 440.44.
NR 439.075(2)(c)1.p.p. Electric arc furnaces and argon-oxygen decarburization vessels at steel plants subject to s. NR 440.445.
NR 439.075(2)(c)1.q.q. Recovery furnaces, smelt dissolving tanks and lime kilns at kraft pulp mills subject to s. NR 440.45.
NR 439.075(2)(c)1.r.r. Melting furnaces at glass manufacturing plants subject to s. NR 440.46.
NR 439.075(2)(c)1.s.s. Kilns at lime manufacturing plants subject to s. NR 440.51.
NR 439.075(2)(c)1.t.t. Control devices at metallic mineral processing plants with sources subject to the requirements of s. NR 440.525.
NR 439.075(2)(c)1.u.u. Dryers, calciners and grinders at phosphate rock plants subject to s. NR 440.54.
NR 439.075(2)(c)1.v.v. Ammonium sulfate dryers at ammonium sulfate manufacturing plants subject to s. NR 440.55.
NR 439.075(2)(c)1.w.w. Saturators and blowing stills at asphalt processing and asphalt roofing manufacturing plants subject to s. NR 440.59.
NR 439.075(2)(c)1.x.x. Rotary spun wool fiberglass insulation manufacturing lines at wool fiberglass insulation plants subject to s. NR 440.69.
NR 439.075(2)(c)2.2. Compliance emission testing for sulfur dioxide is required for fossil fuel fired steam generators subject to s. NR 440.19 or 440.20.
NR 439.075(2)(c)3.3. Compliance emission testing for volatile organic compounds, including a determination of the overall control efficiency of any control device, is required for the following:
NR 439.075(2)(c)3.a.a. Control devices at facilities subject to the surface coating of metal furniture requirements in s. NR 440.48.