NR 661.1087(3)(c)1.1. Following the initial startup of the control device, all activated carbon in the control device shall be replaced with fresh carbon on a regular basis in accordance with the requirements specified in s. NR 661.1033 (7) or (8). NR 661.1087(3)(c)2.2. All carbon that is hazardous waste and that is removed from the control device shall be managed in accordance with the requirements specified in s. NR 661.1033 (14), regardless of the average volatile organic concentration of the carbon. NR 661.1087(3)(d)(d) A remanufacturer or other person that stores or treats the hazardous secondary material using a control device other than a thermal vapor incinerator, flare, boiler, process heater, condenser, or carbon adsorption system to comply with par. (a) shall operate and maintain the control device in accordance with the requirements specified in s. NR 661.1033 (10). NR 661.1087(3)(e)(e) The remanufacturer or other person that stores or treats the hazardous secondary material shall demonstrate that a control device achieves the performance requirements specified in par. (a) as follows: NR 661.1087(3)(e)1.1. A remanufacturer or other person that stores or treats the hazardous secondary material shall demonstrate, using either a performance test as specified in subd. 3. or a design analysis as specified in subd. 4., the performance of each control device except any of the following: NR 661.1087(3)(e)1.b.b. A boiler or process heater with a design heat input capacity of 44 megawatts or greater. NR 661.1087(3)(e)1.c.c. A boiler or process heater into which the vent stream is introduced with the primary fuel. NR 661.1087(3)(e)2.2. A remanufacturer or other person that stores or treats the hazardous secondary material shall demonstrate the performance of each flare in accordance with the requirements specified in s. NR 661.1033 (5). NR 661.1087(3)(e)3.3. For a performance test conducted to meet the requirements specified in subd. 1, the remanufacturer or other person that stores or treats the hazardous secondary material shall use the test methods and procedures specified in s. NR 661.1034 (3) (a) to (d). NR 661.1087(3)(e)5.5. The remanufacturer or other person that stores or treats the hazardous secondary material shall demonstrate that a carbon adsorption system achieves the performance requirements specified in par. (a) based on the total quantity of organics vented to the atmosphere from all carbon adsorption system equipment that is used for organic adsorption, organic desorption or carbon regeneration, organic recovery, and carbon disposal. NR 661.1087(3)(f)(f) If the remanufacturer or other person that stores or treats the hazardous secondary material and the department do not agree on a demonstration of control device performance using a design analysis then the disagreement shall be resolved using the results of a performance test performed by the remanufacturer or other person that stores or treats the hazardous secondary material in accordance with the requirements specified in par. (e) 3. The department may choose to have an authorized representative observe the performance test. NR 661.1087(3)(g)(g) The closed-vent system and control device shall be inspected and monitored by the remanufacture or other person that stores or treats the hazardous secondary material in accordance with the procedures specified in s. NR 661.1033 (6) (b) and (12). The readings from each monitoring device required under s. NR 661.1033 (6) (b) shall be inspected at least once each operating day to check control device operation. Any necessary corrective measures shall be immediately implemented to ensure the control device is operated in compliance with the requirements of this section. NR 661.1087 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20; correction in (3) (e) 3., (g) made under s. 35.17, Stats., Register August 2020 No. 776. NR 661.1088NR 661.1088 Inspection and monitoring requirements. NR 661.1088(1)(1) The remanufacturer or other person that stores or treats the hazardous secondary material shall inspect and monitor air emission control equipment used to comply with this subchapter in accordance with the applicable requirements specified in ss. NR 661.1084 to 661.1087. NR 661.1088(2)(2) The remanufacture or other person that stores or treats the hazardous secondary material shall develop and implement a written plan and schedule to perform the inspections and monitoring required under sub. (1). The remanufacturer or other person that stores or treats the hazardous secondary material shall keep the plan and schedule at the facility. NR 661.1088 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20. NR 661.1089(1)(1) Each remanufacturer or other person that stores or treats the hazardous secondary material subject to requirements of this subchapter shall record and maintain the information specified in subs. (2) to (8), as applicable to the facility. Except for air emission control equipment design documentation and information required by subs. (5) and (8), records required by this section shall be maintained at the facility for a minimum of 3 years. Air emission control equipment design documentation shall be maintained at the facility until the air emission control equipment is replaced or otherwise no longer in service. Information required under subs. (5) and (8) shall be maintained at the facility for as long as the hazardous secondary material management unit is not using air emission controls specified in ss. NR 661.1084 to 661.1087 in accordance with the conditions specified in s. NR 661.1080. NR 661.1089(2)(2) The remanufacturer or other person that stores or treats the hazardous secondary material using a tank with air emission controls in accordance with the requirements under s. NR 661.1084 shall prepare and maintain records for the tank that include all of the following information: NR 661.1089(2)(a)(a) For each tank using air emission controls in accordance with the requirements specified in s. NR 661.1084, the remanufacturer or other person that stores or treats the hazardous secondary material shall record all of the following: NR 661.1089(2)(a)1.1. A tank identification number or other unique identification description as selected by the remanufacturer or other person that stores or treats the hazardous secondary material. NR 661.1089(2)(a)2.b.b. For each defect detected during the inspection, the location of the defect, a description of the defect, the date of detection, and corrective action taken to repair the defect. In the event that repair of the defect is delayed in accordance with the requirements specified in s. NR 661.1084, the remanufacturer or other person that stores or treats the hazardous secondary material shall also record the reason for the delay and the date that completion of repair of the defect is expected. NR 661.1089(2)(b)(b) In addition to the information required under par. (a), the remanufacturer or other person that stores or treats the hazardous secondary material shall record all of the following information, as applicable to the tank: NR 661.1089(2)(b)1.1. The remanufacturer or other person that stores or treats the hazardous secondary material using a fixed roof to comply with the Tank Level 1 control requirements specified in s. NR 661.1084 (3) shall prepare and maintain records for each determination for the maximum organic vapor pressure of the hazardous secondary material in the tank performed in accordance with the requirements specified in s. NR 661.1084 (3). The records shall include the date and time the samples were collected, the analysis method used, and the analysis results.