NR 666.102(5)(c)1.c.c. Appropriate controls on operation and maintenance of the hazardous waste firing system and any air pollution control system.
NR 666.102(5)(c)1.d.d. Allowable variation in boiler and industrial furnace system design including any air pollution control system or operating procedures.
NR 666.102(5)(c)1.e.e. Such other operating requirements as are necessary to ensure that the particulate standard in s. NR 666.111 (2) is met.
NR 666.102(5)(c)2.2. License conditions to ensure conformance with the particulate matter standard may not be provided for facilities exempt from the particulate matter standard under s. NR 666.105 (2).
NR 666.102(5)(c)3.3. For cement kilns and light-weight aggregate kilns, license conditions to ensure compliance with the particulate standard may not limit the ash content of hazardous waste or other feed materials.
NR 666.102(5)(d)(d) Requirements to ensure conformance with the metals emissions standard.
NR 666.102(5)(d)1.1. For conformance with the Tier I (or adjusted Tier I) metals feed rate screening limits of s. NR 666.106 (2) or (5), the license shall specify the following operating requirements:
NR 666.102(5)(d)1.a.a. Total feed rate of each metal in hazardous waste, other fuels, and industrial furnace feedstocks measured and specified under provisions of par. (f).
NR 666.102(5)(d)1.b.b. Total feed rate of hazardous waste measured and specified as prescribed in par. (f).
NR 666.102(5)(d)1.c.c. A sampling and metals analysis program for the hazardous waste, other fuels and industrial furnace feedstocks.
NR 666.102(5)(d)2.2. For conformance with the Tier II metals emission rate screening limits under s. NR 666.106 (3) and the Tier III metals controls under s. NR 666.106 (4), the license shall specify the following operating requirements:
NR 666.102(5)(d)2.a.a. Maximum emission rate for each metal specified as the average emission rate during the trial burn.
NR 666.102(5)(d)2.b.b. Feed rate of total hazardous waste and pumpable hazardous waste, each measured and specified as prescribed in par. (f) 1.
NR 666.102(5)(d)2.c.c. Feed rate of each metal in the following feedstreams, measured and specified as prescribed in par. (f):
1) Total feedstreams.
2) Total hazardous waste feed.
3) Total pumpable hazardous waste feed.
NR 666.102(5)(d)2.d.d. Total feed rate of chlorine and chloride in total feedstreams measured and specified as prescribed in par. (f).
NR 666.102(5)(d)2.e.e. Maximum combustion gas temperature measured at a location indicative of combustion chamber temperature, and measured and specified as prescribed in par. (f).
NR 666.102(5)(d)2.f.f. Maximum flue gas temperature at the inlet to the particulate matter air pollution control system measured and specified as prescribed in par. (f).
NR 666.102(5)(d)2.g.g. Maximum device production rate when producing normal product expressed in appropriate units and measured and specified as prescribed in par. (f).
NR 666.102(5)(d)2.h.h. Appropriate controls on operation and maintenance of the hazardous waste firing system and any air pollution control system.
NR 666.102(5)(d)2.i.i. Allowable variation in boiler and industrial furnace system design including any air pollution control system or operating procedures.
NR 666.102(5)(d)2.j.j. Such other operating requirements as are necessary to ensure that the metals standards under s. NR 666.106 (3) or (4) are met.
NR 666.102(5)(d)3.3. For conformance with an alternative implementation approach approved by the department under s. NR 666.106 (6), the license shall specify all of the following operating requirements:
NR 666.102(5)(d)3.a.a. Maximum emission rate for each metal specified as the average emission rate during the trial burn.
NR 666.102(5)(d)3.b.b. Feed rate of total hazardous waste and pumpable hazardous waste, each measured and specified as prescribed in par. (f) 1.
NR 666.102(5)(d)3.c.c. Feed rate of each metal in the following feedstreams, measured and specified as prescribed in par. (f):
1) Total hazardous waste feed.