NR 254.016(2)(c)(c) Increased loadings, not to exceed 58% above the limitations in par. (a), are allowed for plants which include indirect ammonia recovery systems but only to the extent that such systems generate an increased effluent volume.
NR 254.016(3)(3)Merchant byproduct cokemaking.
NR 254.016(3)(a)(a) The following PSNS apply:
- See PDF for table PDF
NR 254.016(3)(b)(b) Increased loadings, not to exceed 21% above the limitations in par. (a), are allowed for plants which have wet desulfurization systems but only to the extent that such systems generate an increased effluent volume.
NR 254.016(3)(c)(c) Increased loadings, not to exceed 50% above the limitations in par. (a), are allowed for plants which include indirect ammonia recovery systems but only to the extent that such systems generate an increased effluent volume.
NR 254.016 HistoryHistory: Cr. Register, May, 1989, No. 401, eff. 6-1-89.
NR 254.017NR 254.017Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
NR 254.017(1)(1)Except as provided in 40 CFR 125.30 to 125.32, any existing source subject to this subchapter shall achieve the effluent limitations in sub. (2), (3), or (4) representing the degree of effluent reduction attainable by the application of BCT.
NR 254.017(2)(2)Iron and steel byproduct cokemaking.
NR 254.017(2)(a)(a) The following BCT effluent limitations apply:
- See PDF for table PDF
NR 254.017 Note(1) Within the range of 6.0 to 9.0
NR 254.017(2)(b)(b) Increased loadings, not to exceed 11% above the limitations in par. (a), are allowed for plants which have wet desulfurization systems but only to the extent that such systems generate an increased effluent volume.
NR 254.017(2)(c)(c) Increased loadings, not to exceed 27% above the limitations in par. (a), are allowed for plants which include indirect ammonia recovery systems but only to the extent that such systems generate an increased effluent volume.
NR 254.017(3)(3)Merchant byproduct cokemaking.
NR 254.017(3)(a)(a) The following BCT effluent limitations apply:
- See PDF for table PDF
NR 254.017 Note(1) Within the range of 6.0 to 9.0
NR 254.017(3)(b)(b) Increased loadings, not to exceed 10% above the limitations in par. (a), are allowed for plants which have wet desulfurization systems but only to the extent that such systems generate an increased effluent volume.
NR 254.017(3)(c)(c) Increased loadings, not to exceed 25% above the limitations in par. (a), are allowed for plants which include indirect ammonia recovery systems but only to the extent that such systems generate an increased effluent volume.
NR 254.017(4)(4)Beehive cokemaking. Beehive cokemaking operations may not discharge process wastewaters to waters of the state.
NR 254.017 HistoryHistory: Cr. Register, May, 1989, No. 401, eff. 6-1-89.
subch. II of ch. NR 254Subchapter II — Sintering Subcategory
NR 254.02NR 254.02Applicability; description of the sintering subcategory. This subcategory applies to the discharge of pollutants to waters of the state and the introduction of pollutants into POTWs from sintering operations conducted by the heating of iron bearing wastes, such as mill scale and dust from blast furnaces, together with fine iron ore, limestone, and coke fines in an ignition furnace to produce an agglomerate for charging to a blast furnace.
NR 254.02 HistoryHistory: Cr. Register, May, 1989, No. 401, eff. 6-1-89.
NR 254.022NR 254.022Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by application of BPT:
- See PDF for table PDF
NR 254.022 Note(1) Within the range of 6.0 to 9.0