NR 665.1061(2)(a)(a) Conduct a performance test as specified in sub. (3) initially upon designation, annually and at other times requested by the department. NR 665.1061(3)(3) Conduct performance tests according to all of the following: NR 665.1061(3)(b)(b) If an instrument reading of 10,000 ppm or greater is measured, a leak is detected. NR 665.1061(3)(c)(c) Determine the leak percentage by dividing the number of valves subject to s. NR 665.1057 for which leaks are detected, by the total number of valves subject to s. NR 665.1057 within the hazardous waste management unit. NR 665.1061 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 16-007: r. (2) (a), renum. (2) (b), (c) to (2) (a), (b), r. (4) Register July 2017 No. 739, eff. 8-1-17. NR 665.1062NR 665.1062 Alternative standards for valves in gas or vapor service or in light liquid service: skip period leak detection and repair. NR 665.1062(1)(1) An owner or operator subject to s. NR 665.1057 may elect for all valves within a hazardous waste management unit to comply with one of the alternative work practices specified in sub. (2) (b) and (c). NR 665.1062(2)(b)(b) After 2 consecutive quarterly leak detection periods with the percentage of valves leaking equal to or less than 2 percent, an owner or operator may begin to skip one of the quarterly leak detection periods (i.e., monitor for leaks once every 6 months) for the valves subject to s. NR 665.1057. NR 665.1062(2)(c)(c) After 5 consecutive quarterly leak detection periods with the percentage of valves leaking equal to or less than 2 percent, an owner or operator may begin to skip 3 of the quarterly leak detection periods (i.e., monitor for leaks once every year) for the valves subject to s. NR 665.1057. NR 665.1062(2)(d)(d) If the percentage of valves leaking is greater than 2 percent, the owner or operators shall monitor monthly in compliance with s. NR 665.1057, but may again elect to use this section after meeting s. NR 665.1057 (3) (a). NR 665.1062 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 16-007: renum. (1) (a) to (1), r. (1) (b) Register July 2017 No. 739, eff. 8-1-17. NR 665.1063(1)(1) Each owner or operator subject to this subchapter shall comply with the test methods and procedures requirements in this section. NR 665.1063(2)(b)(b) The detection instrument shall meet the performance criteria of Method 21. NR 665.1063(2)(c)(c) Calibrate the instrument before use on each day of its use by the procedures in Method 21. NR 665.1063(2)(d)2.2. A mixture of methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane. NR 665.1063(2)(e)(e) Traverse the instrument probe around all potential leak interfaces as close to the interface as possible as described in Method 21. NR 665.1063(3)(c)(c) Traverse the instrument probe around all potential leak interfaces as close to the interface as possible as described in Method 21.