DOC 350.06(3)(f)1.1. A rigidly constructed metal bed with the frame bracketed to the wall or bolted to the floor or a bed built in masonry construction of a similar strength for each inmate. DOC 350.06(3)(f)2.2. A detention strength, metal, institution-type washbasin and toilet. The washbasin and toilet may be combined in one unit. The washbasin shall have hot and cold running water. DOC 350.06(3)(f)3.3. Detention strength light fixtures that shall provide at least 10 foot-candles of illumination, 30 inches above the floor. Lights shall have a dimming capability or there shall be a night light to allow for comfortable sleeping. DOC 350.06(3)(f)4.4. A detention strength, metal, institution-type mirror that is not removable. DOC 350.06(4)(a)(a) All dormitories and cells, except receiving cells and holding rooms, shall be provided with one or more dayrooms in their immediate vicinity that are accessible to inmates. If the dayroom is an area within a dormitory, the requirements under sub. (6) (b) apply. DOC 350.06(4)(b)(b) Each dayroom shall have detention strength tables and seating for the number of occupants of the dormitory or cells that have access to the dayroom. DOC 350.06(4)(c)(c) Illumination in dayrooms may not be less than 10 foot-candles, 30 inches above the floor. DOC 350.06(5)(a)(a) All receiving cells shall be designed and used for single occupancy. DOC 350.06(5)(b)(b) Each receiving cell shall have a floor area of at least 54 square feet. The distance between the floor and ceiling may not be less than 8 feet and the distance between opposite walls may not be less than 6 feet. DOC 350.06(5)(c)1.1. A rigidly constructed metal bed with the frame bracketed to the wall or bolted to the floor or a bed built in masonry construction of a similar strength. DOC 350.06(5)(c)2.2. A detention strength, metal, institution-type washbasin and toilet. The washbasin and toilet may be combined in one unit. The washbasin shall have hot and cold running water. DOC 350.06(5)(c)3.3. Detention strength light fixtures that shall provide at least 10 foot-candles of illumination, 30 inches above the floor. Lights shall have a dimming capability or there shall be a night light to allow for comfortable sleeping. DOC 350.06(6)(a)(a) Inmates may be housed in dormitories if the inmates are of the same security classification and properly segregated as required under s. 302.36, Stats. DOC 350.06(6)(b)(b) Each dormitory shall have a minimum floor area of 35 square feet per occupant, excluding the toilet and shower area. Each dormitory shall have a floor to ceiling height of not less than 8 feet. DOC 350.06(6)(c)(c) A detention strength bed shall be provided for each occupant of a dormitory. DOC 350.06(6)(d)(d) An area for personal property shall be provided for each occupant of a dormitory. DOC 350.06(6)(e)(e) Dormitories shall be provided with illumination of at least 10 foot-candles, 30 inches above the floor and with the ability to reduce lighting during sleeping hours to a level which is enough for security checks. DOC 350.06(6)(f)(f) Each dormitory shall provide adequate showers or bathtubs, toilets, and washbasins for the occupants. Each dormitory shall have hot and cold running water, and the hot water shall maintain a minimum temperature of 110°F to the mixer. In this paragraph, “mixer” means the part of the plumbing system which combines hot and cold water. DOC 350.06(6)(g)(g) Dormitories shall be constructed of materials of detention strength and shall be provided with detention strength equipment. DOC 350.06(7)(a)(a) Holding rooms are intended to be used for admission, release, and investigative purposes. A holding room may not be used as a cell, dormitory, or receiving cell. Holding rooms shall be located in an area that allows continuous staff observation or electronic video surveillance of inmates. DOC 350.06(7)(b)(b) Each holding room shall contain detention strength, rigidly constructed seats or benches bracketed to the wall or bolted to the floor or seats or benches of masonry construction of a similar strength. DOC 350.06(7)(c)(c) A detention strength, institution-type washbasin and toilet shall be provided. DOC 350.06(7)(d)(d) A holding room shall have a floor area of at least 50 square feet with an additional 10 square feet for each occupant above five. DOC 350.06(8)(8) Multipurpose room. Each jail shall provide a multipurpose room for recreation, physical exercise, and congregate assembly other than visiting. The multipurpose room shall have a minimum floor area of 300 square feet.