NR 466.06(4)(a)1.c.c. Determine the volatile matter content, including water, of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month following the procedure in s. NR 466.09 (3) (a).
NR 466.06(4)(a)1.d.d. Install, calibrate, maintain and operate, according to the manufacturer’s specifications, a device that indicates the cumulative amount of volatile matter recovered by the solvent recovery device on a monthly basis. The device shall be initially certified by the manufacturer to be accurate to within +2.0%.
NR 466.06(4)(a)1.e.e. Measure the amount of volatile matter recovered for the month.
NR 466.06(4)(a)1.f.f. Calculate the overall effective organic HAP control efficiency (Re) for the month using Equation 1. For the purposes of this calculation, the mass fraction of organic HAP present in the recovered volatile matter is assumed to be equal to the mass fraction of organic HAP present in the volatile matter used.
(Equation 1)
NR 466.06(4)(a)2.2. Use continuous emission monitors, conduct an initial performance test of capture efficiency, and continuously monitor a site specific operating parameter to assure capture efficiency as specified in the following procedures:
NR 466.06(4)(a)2.a.a. Install continuous emission monitors to determine the total organic volatile matter mass flow rate at both the inlet to and the outlet from the control device, and calculate the percent efficiency (E) of the control device for each month.
NR 466.06(4)(a)2.b.b. Determine the percent capture efficiency (F) of the capture system according to s. NR 466.09 (5).
NR 466.06(4)(a)2.c.c. Calculate the overall effective organic HAP control efficiency (Re) achieved for each month using Equation 2.
(Equation 2)
NR 466.06(4)(a)2.d.d. Install, calibrate, operate and maintain the instrumentation necessary to measure continuously the site-specific operating parameter established in accordance with s. NR 466.10 (6) whenever a publication rotogravure printing press is operated.
NR 466.06(4)(a)2.e.e. Operate the capture device at an average value greater than, or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6) for each 3-hour period.
NR 466.06(4)(b)(b) Oxidation. Each owner or operator using an oxidizer to control emissions shall demonstrate compliance by showing that the HAP emission limitation is achieved by doing either of the following:
NR 466.06(4)(b)1.1. Demonstrate initial compliance through performance tests and continuing compliance through continuous monitoring according to the following procedures:
NR 466.06(4)(b)1.a.a. Determine the oxidizer destruction efficiency (E) using the procedure in s. NR 466.09 (4).
NR 466.06(4)(b)1.b.b. Determine the capture efficiency (F) using the procedure in s. NR 466.09 (5).
NR 466.06(4)(b)1.c.c. Calculate the overall effective organic HAP control efficiency (Re) achieved using Equation 2 in par. (a) 2. c.
NR 466.06(4)(b)1.d.d. Continuously monitor an appropriate oxidizer operating parameter in accordance with s. NR 466.10 (5), and continuously monitor an appropriate capture system monitoring parameter in accordance with s. NR 466.10 (6).
NR 466.06(4)(b)1.e.e. Operate the capture device at an average value greater than or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6).
NR 466.06(4)(b)1.f.f. If an oxidizer other than a catalytic oxidizer is used, operate the oxidizer at an average combustion temperature for all 3-hour periods greater than or equal to the average combustion temperature established under s. NR 466.09 (4).
NR 466.06(4)(b)1.g.g. If a catalytic oxidizer is used, operate the oxidizer so that the average catalyst bed inlet temperature for all 3-hour periods is greater than or equal to the average catalyst bed inlet temperature established under s. NR 466.09 (4).
NR 466.06(4)(b)2.2. Use continuous emission monitors, conduct an initial performance test of capture efficiency and continuously monitor a site specific operating parameter to assure capture efficiency in accordance with the requirements of par. (a) 2.
NR 466.06(4)(c)(c) Low HAP materials. . Each owner or operator demonstrating compliance without the use of a control device shall compare the mass of organic HAP used to the mass of volatile matter used each month, as specified in the following procedures:
NR 466.06(4)(c)1.1. Measure the mass of each ink, coating, varnish, adhesive, primer, solvent and other material used in the affected source during the month.
NR 466.06(4)(c)2.2. Determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent and other material used during the month following the procedure in s. NR 466.09 (2) (a).
NR 466.06(4)(c)3.3. Determine the volatile matter content, including water, of each ink, coating, varnish, adhesive, primer, solvent and other material used during the month following the procedure in s. NR 466.09 (3) (a).
NR 466.06(4)(d)(d) Compliance criteria.