NR 670.305(6)(6) For new tank systems, a detailed description of how the tank system or systems will be installed in compliance with ss. NR 667.0192 and 667.0194. NR 670.305(7)(7) Detailed plans and description of how the secondary containment system for each tank system is or will be designed, constructed and operated to meet the requirements of ss. NR 667.0195 and 667.0196. NR 670.305(9)(9) Description of controls and practices to prevent spills and overflows, as required under s. NR 667.0198. NR 670.305(10)(10) For tank systems in which ignitable, reactive, or incompatible wastes are to be stored or treated, a description of how operating procedures and tank system and facility design shall achieve compliance with the requirements of ss. NR 667.0202 and 667.0203. NR 670.305 HistoryHistory: CR 16-007: cr. Register July 2017 No. 739, eff. 8-1-17; correction in (4) made under s. 35.17, Stats., Register July 2017 No. 739. NR 670.310NR 670.310 What equipment information shall I keep at my facility? If your facility has equipment to which subch. BB of ch. NR 664 applies, keep the following information at your facility: NR 670.310(1)(a)(a) Equipment identification number and hazardous waste management unit identification. NR 670.310(1)(b)(b) Approximate locations within the facility (for example, identify the hazardous waste management unit on a facility plot plan). NR 670.310(1)(c)(c) Type of equipment (for example, a pump or a pipeline valve). NR 670.310(1)(d)(d) Percent by weight of total organics in the hazardous waste stream at the equipment. NR 670.310(1)(e)(e) Hazardous waste state at the equipment (for example, gas, vapor, or liquid). NR 670.310(1)(f)(f) Method of compliance with the standard (for example, monthly leak detection and repair or equipped with dual mechanical seals). NR 670.310(3)(3) Documentation that demonstrates compliance with the equipment standards in ss. NR 6264.1052 and 664.1059. This documentation shall contain the records required under s. NR 664.1064. NR 670.310(4)(a)(a) A list of all information references and sources used in preparing the documentation. NR 670.310(4)(c)(c) A design analysis, specifications, drawings, schematics and piping and instrumentation diagrams based on the appropriate sections of “Course 415: Control of Gaseous Emissions,” incorporated by reference in s. NR 660.11, or other engineering texts acceptable to the department that present basic control device design information. The design analysis shall address the vent stream characteristics and control device operation parameters as specified in s. NR 664.1035 (2) (d) 3. NR 670.310(4)(d)(d) A statement signed and dated by the owner or operator certifying that the operating parameters used in the design analysis reasonably represent the conditions that exist when the hazardous waste management unit is operating at the highest load or capacity level reasonable expected to occur. NR 670.310(4)(e)(e) A statement signed and dated by the owner or operator certifying that the control device is designed to operate at an efficiency of 95 weight percent or greater. NR 670.310 HistoryHistory: CR 16-007: cr. Register July 2017 No. 739, eff. 8-1-17. NR 670.315NR 670.315 What air emissions control information shall I keep at my facility? If you have air emission control equipment subject to subch. CC of ch. NR 664, keep the following information at your facility: NR 670.315(1)(1) Documentation for each floating roof cover installed on a tank subject to s. NR 664.1084 (4) (a) or (b) that includes information you prepared or the cover manufacturer or vendor provided describing the cover design, and your certification that the cover meets applicable design specifications listed in s. NR 664.1084 (5) (a) or (6) (a). NR 670.315(2)(2) Identification of each container area subject to the requirements of subch. CC of ch. NR 664 and your certification that the requirements of the subchapter are met. NR 670.315(3)(3) Documentation for each enclosure used to control air pollutant emissions from tanks or containers under requirements of s. NR 664.1084 (4) (e) or 664.1086 (5) (a) 2. Include records for the most recent set of calculations and measurements you performed to verify that the enclosure meets the criteria of a permanent total enclosure as specified in “Procedure T — Criteria for and Verification of a Permanent or Temporary Total Enclosure” under 40 CFR 52.741, Appendix B. NR 670.315(5)(5) Documentation for each closed vent system and control device installed under requirements of s. NR 664.1087 that includes design and performance information as specified in s. NR 670.024 (3) and (4). NR 670.315(6)(6) An emission monitoring plan for both Method 21 in 40 CFR part 60, Appendix A and control device monitoring methods. This plan shall include the following information: monitoring points, monitoring methods for control devices, monitoring frequency, procedures for documenting exceedances, and procedures for mitigating non-compliance.