NR 422.143(5)(b)1.1. Install and operate continuous temperature monitoring and recording equipment that measures and records any of the following temperature of the control device at least once every 15 minutes: NR 422.143(5)(b)1.a.a. The combustion chamber or minimum operating temperature for thermal oxidizers. NR 422.143(5)(b)3.3. Maintain the 3-hour average temperature at or above any of the following levels when the associated printing press is in operation: NR 422.143(5)(b)3.a.a. 50°F below the minimum operating temperature specified by the manufacturer for regenerative thermal oxidizers. NR 422.143(5)(b)3.b.b. 50°F below the average temperature measured during the most recent emission test that demonstrated compliance for all other type of oxidizers. NR 422.143(5)(b)4.4. For catalytic oxidizers, inspect the catalyst bed material annually for general catalyst condition and any signs of potential catalyst depletion. The owner or operator shall also collect a representative sample of the catalyst from the catalytic oxidizer, in accordance with manufacturer’s recommendations, and have it tested to evaluate the catalyst’s capability to continue to function at or above the required control efficiency. An evaluation of the catalyst bed material shall be conducted whenever the results of the inspection indicate signs of potential catalyst depletion or poor catalyst condition based on manufacturer’s recommendations, but not less than once per year. NR 422.143(5)(b)5.5. Perform maintenance for the control devices in accordance with manufacturer’s recommendations. NR 422.143(6)(6) Recordkeeping requirements. In addition to the applicable recordkeeping requirements in s. NR 439.04, the owner or operator of any lithographic printing press shall collect and record the applicable information specified in this subsection. The information shall be maintained at the facility for a minimum of 5 years and shall be made available to an authorized department representative at any time during normal working hours. The information required is all of the following: NR 422.143(6)(a)(a) For a heatset web lithographic printing press using a control device, all of the following: NR 422.143(6)(a)2.2. A log or record of any time when the control device or control device monitoring equipment is offline while the associated printing line is in operation. NR 422.143(6)(a)3.3. A maintenance log for the control device and control device monitoring equipment detailing all maintenance performed and including the dates and duration of any outages. NR 422.143(6)(b)(b) For fountain solutions monitored under sub. (5), the fountain solution reservoir temperature for each 8-hour shift of operation. NR 422.143(6)(c)(c) For each fountain solution used, the percent by weight VOC content as applied, and the CAS number and chemical name of each restricted alcohol. NR 422.143(6)(d)(d) For each cleaning solution prepared, the percent by weight VOC content or the VOC composite partial vapor pressure for the cleaning solution prepared. NR 422.143(6)(e)(e) For each month of operation, the volume of all cleaning solutions used that do not meet either of the emission limitations in sub. (3) (c). NR 422.143(7)(a)(a) The owner or operator of a heatset web lithographic printing press shall demonstrate compliance with the appropriate destruction efficiency or emission rate in sub. (3) (a) by performing compliance emission tests on each control device. The initial emission tests shall be performed by the compliance deadline in sub. (8) (am). Each emission test shall follow the methods and procedures listed in s. NR 439.07. Method 18, 25 or 25A in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (16), (19) and (20), shall be used to determine the VOC concentration at the sampling points. When determining the VOC concentration, the probe shall be heated during testing to at least the exhaust gas stream temperature. NR 422.143(7)(b)(b) The owner or operator of a heatset web lithographic printing press shall perform the compliance emission tests required under par. (a) according to one of the following applicable test schedules: NR 422.143(7)(b)1.1. Any facility with allowable VOC emissions from lithographic printing presses of 100 tons or more per year shall perform an emission test that demonstrates compliance with sub. (3) (a) every 24 months. Each biennial test shall be performed within 90 days of the anniversary date of the initial emission test or an alternate date approved by the department. The testing exceptions listed in s. NR 439.075 (4) may apply to this test schedule. NR 422.143(7)(b)2.2. Any facility with allowable VOC emissions from lithographic printing presses of less than 100 tons per year shall perform an initial emission test that demonstrates compliance with sub. (3) (a). NR 422.143(7)(c)(c) The VOC content of the as-applied fountain solutions and cleaning solutions shall be determined by any of the following methods: NR 422.143(7)(c)2.2. If diluted prior to use, a calculation shall be performed for VOC content that combines the method referred in s. NR 439.06 (3) (j) for the concentrated materials used to prepare the as-applied fountain solution or cleaning solution, and the proportions in which they are mixed to make the as-applied fountain solution or cleaning solution. NR 422.143(7)(d)(d) The VOC composite partial vapor pressure of each cleaning solution shall be determined by any of the following methods: NR 422.143(7)(d)1.1. If diluted prior to use, calculate the VOC composite vapor pressure of the as-applied solvent by using the formula for “VOC composite vapor pressure” as follows: