NR 422.131(3)(c)(c) Convey VOC-containing coatings, thinners, and cleaning materials in closed containers or pipes.
NR 422.131(3)(d)(d) Minimize spills of VOC-containing coating, thinners, and cleaning materials.
NR 422.131(3)(e)(e) Minimize emissions of VOC during cleaning of coating application, storage, mixing, and conveying equipment.
NR 422.131(3)(f)(f) Clean-up spills of any VOC-containing material immediately.
NR 422.131 HistoryHistory: CR 08-102: cr. Register July 2009 No. 643, eff. 8-1-09.
NR 422.132NR 422.132Wood door coating.
NR 422.132(1)(1)Applicability.
NR 422.132(1)(am)(am) Except as provided in par. (bm), this section applies to the wood entry or passage door coating lines of any wood entry or passage door coating facility that is either of the following:
NR 422.132(1)(am)1.1. Located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Washington, or Waukesha and which has maximum theoretical emissions of VOC from all wood entry or passage door coating at the facility greater than or equal to 25 tons per year.
NR 422.132(1)(am)2.2. Located in the county of Kewaunee, Manitowoc, or Sheboygan and which has maximum theoretical emissions of VOC from all wood entry or passage door coating at the facility greater than or equal to 100 tons per year.
NR 422.132(1)(bm)(bm) This section does not apply to either of the following:
NR 422.132(1)(bm)1.1. Flat wood panel coating lines subject to s. NR 422.13.
NR 422.132(1)(bm)2.2. Adhesives and adhesive primers subject to s. NR 422.127.
NR 422.132(2)(2)Emission limitations and application requirements.
NR 422.132(2)(a)(a) No owner or operator of an automated wood entry or passage door coating line may cause, allow or permit the emission of any VOCs in excess of:
NR 422.132(2)(a)1.1. 0.77 kilograms per liter (6.9 pounds per gallon) of coating, excluding water, delivered to an applicator that applies any coating on or after May 31, 1995, but before May 1, 1997.
NR 422.132(2)(a)2.2. 0.64 kilograms per liter (5.7 pounds per gallon) of coating, excluding water, delivered to an applicator that applies any coating on or after May 1, 1997.
NR 422.132(2)(b)(b) An owner or operator of a wood entry or passage door coating facility shall only apply coatings using electrostatic application, flow coating, dip coating, a low-pressure spray method, paint brush, hand roller or roll coater. All applications equipment shall be in proper operating condition and used in accordance with proper operating procedures.
NR 422.132(3)(3)Recordkeeping requirements. Any facility subject to this section shall comply with the requirements applicable under s. NR 439.04 (5).
NR 422.132 HistoryHistory: Cr. Register, August, 1994, No. 464, eff. 9-1-94; r. and recr. (1) (c), Register, August, 1995, No. 476, eff. 9-1-95; CR 11-005: renum. (1) (intro.) to be (1) (am) (intro.) and am., r. (1) (a), cr. (1) (am) 1., 2., (bm) (intro.), renum. (1) (b), (c) to be (1) (bm) 1., 2. Register January 2012 No. 673, eff. 2-1-12.
NR 422.135NR 422.135Molded wood parts or products.
NR 422.135(1)(1)Applicability.
NR 422.135(1)(am)(am) Except as provided in par. (b), this section applies to molded wood parts or products coating lines of any molded wood parts or products coating facility that is either of the following:
NR 422.135(1)(am)1.1. Located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Washington, or Waukesha and which has maximum theoretical emissions of VOC from all wood entry or passage door coating at the facility greater than or equal to 25 tons per year.
NR 422.135(1)(am)2.2. Located in the county of Kewaunee, Manitowoc, or Sheboygan and which has maximum theoretical emissions of VOC from all wood entry or passage door coating at the facility greater than or equal to 100 tons per year.
NR 422.135(1)(b)(b) This section does not apply to the use of topcoats which are applied as a stripe not more than 1/2 inch in width to croquet balls and whose use in aggregate never exceeds 500 gallons in a year, as applied.
NR 422.135(2)(2)Emission limitations.
NR 422.135(2)(a)(a) No owner or operator of a molded wood parts or products coating facility which uses flow coating to apply topcoats may cause, allow or permit the emission of any VOCs in excess of the limitations specified in Table 3.
NR 422.135(2)(b)(b) No owner or operator of a molded wood parts or products coating facility which applies a topcoat using any application method other than flow coating may cause, allow or permit the emission of any VOCs in excess of the limitations specified in Table 4.