NR 440.76(14)(c)2.2. You shall keep records of results of all opacity tests onsite in either paper copy or electronic format unless the department approves another format. NR 440.76(14)(c)3.3. You shall keep all records for each incinerator for at least 5 years. NR 440.76(14)(c)4.4. You shall make all records available for submittal to the department or for onsite review by an inspector. NR 440.76(14)(c)5.5. You shall submit the results (each 6-minute average) of the opacity tests by February 1 of the year following the year of the opacity emission test. NR 440.76(14)(c)6.6. You shall submit reports as a paper copy on or before the applicable submittal date. If the department agrees, you may submit reports on electronic media. NR 440.76(15)(a)(a) Concentration correction to 7% oxygen. You shall correct any pollutant concentration to 7% oxygen using the following equation: where:
C7% is the concentration corrected to 7% oxygen
Cunc is the uncorrected pollutant concentration
O2 is the concentration of oxygen, percent
NR 440.76(15)(b)(b) Percent reduction in potential mercury emissions. You shall calculate the percent reduction in potential mercury emissions (%PHg) using the following equation: where:
%PHg is the percent reduction of potential mercury emissions
Ei is the mercury emission concentration as measured at the air pollution control device inlet, corrected to 7% oxygen, dry basis
Eo is the mercury emission concentration as measured at the air pollution control device outlet, corrected to 7% oxygen, dry basis
NR 440.76(15)(c)(c) Percent reduction in potential hydrogen chloride emissions. You shall calculate the percent reduction in potential hydrogen chloride emissions (%PHCl) using the following equation: where:
%PHCl is the percent reduction of the potential hydrogen chloride emissions
Ei is the hydrogen chloride emission concentration as measured at the air pollution control device inlet, corrected to 7% oxygen, dry basis
Eo is the hydrogen chloride emission concentration as measured at the air pollution control device outlet, corrected to 7% oxygen, dry basis