NR 440.76(11)(d)3.a.a. Exclude hours when the municipal waste combustion unit is not operating.
NR 440.76(11)(d)3.b.b. Include hours when the municipal waste combustion unit is operating but the carbon feed system is not working correctly.
NR 440.76(11)(e)(e) What is the minimum amount of monitoring data I must collect with my continuous parameter monitoring systems and is the data collection requirement enforceable?
NR 440.76(11)(e)1.1. Where continuous parameter monitoring systems are used, you shall obtain 1-hour arithmetic averages for the following 3 parameters:
NR 440.76(11)(e)1.a.a. Load level of the municipal waste combustion unit.
NR 440.76(11)(e)1.b.b. Temperature of the flue gases at the inlet of your particulate matter control device.
NR 440.76(11)(e)1.c.c. Carbon feed rate if activated carbon is used to control dioxins/furans or mercury emissions.
NR 440.76(11)(e)2.2. You shall obtain at least 2 data points per hour in order to calculate a valid 1-hour arithmetic average.
NR 440.76(11)(e)3.3. You shall obtain valid 1-hour averages for at least 75% of the operating hours per day for 90% of the operating days per calendar quarter. An operating day is any day the unit combusts any municipal solid waste or refuse-derived fuel.
NR 440.76(11)(e)4.4. If you do not obtain the minimum data required in subds. 1. to 3., you are in violation of the data collection requirement and you shall notify the department according to sub. (13) (h) 5.
NR 440.76(12)(12)Recordkeeping.
NR 440.76(12)(a)(a) What records must I keep? You shall keep 5 types of records:
NR 440.76(12)(a)1.1. Materials separation plan and siting analysis.
NR 440.76(12)(a)2.2. Operator training and certification.
NR 440.76(12)(a)3.3. Stack tests.
NR 440.76(12)(a)4.4. Continuously monitored pollutants and parameters.
NR 440.76(12)(a)5.5. Carbon feed rate.
NR 440.76(12)(b)(b) Where must I keep my records and for how long?
NR 440.76(12)(b)1.1. You shall keep all records onsite in paper copy or electronic format unless the department approves another format.
NR 440.76(12)(b)2.2. You shall keep all records on each municipal waste combustion unit for at least 5 years.
NR 440.76(12)(b)3.3. You shall make all records available for submittal to the department, or for onsite review by an inspector.
NR 440.76(12)(c)(c) What records must I keep for the materials separation plan and siting analysis? You shall keep records of the following 5 items:
NR 440.76(12)(c)1.1. The date of each record.
NR 440.76(12)(c)2.2. The final materials separation plan.
NR 440.76(12)(c)3.3. The siting analysis.
NR 440.76(12)(c)4.4. A record of the location and date of the public meetings.
NR 440.76(12)(c)5.5. Your responses to the public comments received during the public comment periods.
NR 440.76(12)(d)(d) What records must I keep for operator training and certification? You shall keep records of the following 6 items:
NR 440.76(12)(d)1.1. ‘Records of provisional certifications.’ The following 3 items shall be included: