AIR CONTAMINANT EMISSIONS INVENTORY REPORTING REQUIREMENTS
NR 438.01   Applicability; purpose.
NR 438.02   Definitions.
NR 438.03   Required emissions inventories.
NR 438.04   Content of emissions inventories.
Ch. NR 438 NoteNote: Correction made under s. 13.93 (2m) (b) 7., Stats., Register, December, 1996, No. 492.
NR 438.01NR 438.01Applicability; purpose.
NR 438.01(1)(1)Applicability. This chapter applies to all air contaminant sources and to their owners and operators.
NR 438.01(2)(2)Purpose. The purpose of this chapter is to establish, pursuant to ss. 285.11, 285.13, 285.17, and 299.15 (1) and (2), Stats., requirements for submission of emissions inventories for owners or operators of air contaminant sources.
NR 438.01 HistoryHistory: Cr. Register, May, 1993, No. 449, eff. 6-1-93; CR 21-072: am. (2) Register July 2022 No. 799, eff. 8-1-22.
NR 438.02NR 438.02Definitions. The definitions contained in ch. NR 400 apply to the terms used in this chapter. In addition, the following definitions apply to the terms used in this chapter:
NR 438.02(1a)(1a)“Condensable PM” means a material that is vapor phase at stack conditions but that condenses or reacts upon cooling and dilution in the ambient air to form solid or liquid PM immediately after discharge from the stack.
NR 438.02 NoteNote: Condensable PM, if present from a source, is typically in the PM2.5 size fraction and, therefore, all of it is a component of both primary PM2.5 and primary PM10.
NR 438.02(1e)(1e)“Facility” means all stationary sources emitting air contaminants which belong to the same industrial grouping, are located on one or more contiguous or adjacent properties, and are under the control of the same person, or persons under common control. Emissions resulting from loading, unloading or stockpiling materials to or from vessels or vehicles while at a facility shall be considered as part of the facility’s emissions. Air contaminant sources, other than transportation related activities, shall be considered as part of the same industrial grouping if they are classified under the same 2-digit major group as described in the Standard Industrial Classification Manual, 1987, incorporated by reference in s. NR 484.05 (1).
NR 438.02(1g)(1g)“Filterable PM” means particles that have an aerodynamic diameter equal to or less than 100 micrometers that are directly emitted by a source as a solid or liquid at stack or release conditions and captured on the filter of a stack test train.
NR 438.02(1i)(1i)“Filterable PM2.5” means particles that have an aerodynamic diameter equal to or less than 2.5 micrometers that are directly emitted by a source as a solid or liquid at stack or release conditions and captured on the filter of a stack test train.
NR 438.02(1k)(1k)“Filterable PM10” means particles that have an aerodynamic diameter equal to or less than 10 micrometers that are directly emitted by a source as a solid or liquid at stack or release conditions and captured on the filter of a stack test train.
NR 438.02(1m)(1m)“Primary PM” means the sum of filterable PM and condensable PM.
NR 438.02(1o)(1o)“Primary PM2.5” means the sum of filterable PM2.5 and condensable PM.
NR 438.02(1q)(1q)“Primary PM10” means the sum of filterable PM10 and condensable PM.
NR 438.02(1s)(1s)“Process” means an activity occurring at a unit device that generates emissions, controls emissions, or discharges emissions.
NR 438.02 NoteNote: Examples of processes include combustion, coating, controlling, crushing, or discharging.
NR 438.02(1u)(1u)“Process type code” means a brief descriptor of the process type.
NR 438.02(2)(2)“Source classification code” means a process-level code that describes the equipment or operation that is emitting a pollutant.
NR 438.02 NoteNote: Source classification codes are available as set forth by EPA’s Emissions Inventory System, which is an information system for storing all current and historical emissions inventory data.
NR 438.02(3)(3)“Unit device” means the physical equipment or equipment line where a process occurs.
NR 438.02 NoteNote: Examples of unit devices include boilers, coating lines, baghouses, and stacks.
NR 438.02(4)(4)“Unit device type code” means a brief descriptor of the unit device type.
NR 438.02 HistoryHistory: Cr. Register, May, 1993, No. 449, eff. 6-1-93; am. (1), (2), Register, February, 1995, No. 470, eff. 3-1-95; am. (2), Register, October, 1999, No. 526, eff. 11-1-99; CR 21-072: renum. (1) to (1e), cr. (1a), (1g), (1i), (1k), (1m), (1o), (1q), (1s), (1u), r. and recr. (2), cr. (3), (4) Register July 2022 No. 799, eff. 8-1-22.
NR 438.03NR 438.03Required emissions inventories.
NR 438.03(1)(1)Reportable air contaminants and levels.
NR 438.03(1)(a)(a) Except as provided under par. (am), any person owning or operating a facility that emits an air contaminant in quantities above applicable reporting levels, except indirect sources of air pollution, shall annually submit to the department an emissions inventory of annual, actual emissions or, for primary particulate matter, primary PM10, primary PM2.5, sulfur dioxide, nitrogen oxides, carbon monoxide and volatile organic compounds, throughput information sufficient for the department to calculate its annual, actual emissions. The reportable air contaminants and applicable reporting levels are listed in Table 1 in this chapter.
NR 438.03(1)(af)(af) The owner or operator of a facility shall annually submit to the department an emissions inventory for sulfur dioxide, nitrogen oxides, carbon monoxide, volatile organic compounds, primary PM10, primary PM2.5, ammonia, and lead and lead compounds, if the facility meets any of the following:
NR 438.03(1)(af)1.1. The facility is a Part 70 major source, as defined under 40 CFR 70.2.
NR 438.03(1)(af)2.2. The facility is a nonattainment area major source, as defined under s. NR 408.02 (21).
NR 438.03(1)(af)3.3. The facility has the potential to emit equal to or greater than 100 tons per year of ammonia.
NR 438.03(1)(af)4.4. The facility has actual emissions equal to or greater than 0.5 ton per year of lead.
NR 438.03(1)(am)1.1. The owner or operator of a facility described by an SIC code listed in Table D of s. NR 445.11, or that has annual actual emissions of less than 5 tons of particulate matter and less than 3 tons of volatile organic compounds, may limit the information on hazardous air contaminants included in the annual emissions inventory to those contaminants identified under s. NR 445.11 (1) (a) or (b).
NR 438.03(1)(am)2.2. Notwithstanding subd. 1., the owner or operator shall continue to report annual emissions of any air contaminant reported in prior calendar years for the facility, provided annual, actual emissions are greater than the reporting level in Table 1.
NR 438.03(1)(am)3.3. The owner or operator of a facility may exclude emissions from any of the following emissions units, operations, or activities from the annual emissions inventory:
NR 438.03(1)(am)3.a.a. Maintenance of grounds, equipment, and buildings, including lawn care, pest control, grinding, cutting, welding, painting, woodworking, general repairs, and cleaning, but not including use of organic compounds as clean-up solvents.
NR 438.03(1)(am)3.b.b. Boiler, turbine, generator, heating, and air conditioning maintenance.
NR 438.03(1)(am)3.c.c. Pollution control equipment maintenance.
NR 438.03(1)(am)3.d.d. Fire control equipment.
NR 438.03(1)(am)3.e.e. Janitorial activities.
NR 438.03(1)(am)3.f.f. Office activities.
NR 438.03(1)(am)3.g.g. Convenience water heating.
NR 438.03(1)(am)3.h.h. Convenience space heating units with combined heat input capacity of less than 5 million Btu per hour that burn gaseous fuels or liquid fuels.
NR 438.03(1)(am)3.i.i. Fuel oil storage tanks with a combined capacity of 10,000 gallons or less.
NR 438.03(1)(am)3.j.j. Stockpiled contaminated soils.
NR 438.03(1)(am)3.k.k. Demineralization and oxygen scavenging of water for boilers.
NR 438.03(1)(am)3.L.L. Purging of natural gas lines.
NR 438.03(1)(am)4.4. The owner or operator of a facility with emissions exceeding the reporting thresholds in this section shall include all emission units, operations, or activities in the annual emissions inventory. The owner or operator of a facility may exclude emissions information required under s. NR 438.04 (3) (d) for any emissions unit, operation, or activity that meets the criteria under s. NR 407.05 (4) (c) 9. a. If the department determines that an emission unit, operation, or activity does not meet the criteria under s. NR 407.05 (4) (c) 9. a., the owner or operator shall include the emissions in the annual emissions inventory.
NR 438.03(1)(b)(b) When preparing an emissions inventory, the owner or operator of a facility may rely on information in an approved safety data sheet. Trace contaminants need not be reported if they constitute less than 1 percent (10,000 parts per million) of the material, or 0.1 percent (1,000 parts per million) of the material if the air contaminant is listed with a control requirement under column (i) of Table A, B or C of s. NR 445.07, unless a hazardous air contaminant is formed in processing the material.
NR 438.03(1)(c)(c) Notwithstanding par. (a), the department may require any facility to submit an emissions inventory of its annual, actual and maximum theoretical air contaminant emissions.
Loading...